Digital halls can be used for commutation, position and velocity control. Resolution using these sensors is much lower than using encoders. Jupiter can use single
ended Hall sensors to drive the motor with trapezoidal commutation, but not with sinusoidal commutation.
This interface accepts 0-5 V level input signals. Inputs are pulled up to 5 V, so industry standard open collector and logic output hall effect sensors can be
connected. Next table summarizes digital halls inputs main features:
Specification
Value
Type of inputs
Non-isolated
Single ended with pull-up and low pass filter
ESD protected
Number of inputs
3
ESD capability
IEC 61000-4-2 (ESD) ± 15 kV (air), ± 8 kV (contact)
IEC 61000-4-4 (EFT) 40 A (5/50 ns)
Voltage range
0 ~ 5 V
Maximum voltage range
-0.5 ~ 5.5 V
Maximum working frequency
50 kHz (limited by noise filter)
Type of sensors
Open collector
Logic output
Push-pull output
Pull-up resistor value
1 kΩ (The pull-up is activated only when the driver is configured to use digital hall sensors)