Everest XCR - Product Manual |
Wiring and Connections
INGENIA | 08/04/2019
50
Specification
Value
Type of inputs
Non-isolated
Differential or single ended
ESD protected
Number of inputs
3 (A, B and Index)
ESD capability
IEC 61000-4-2 (ESD) ± 30 kV (air), ± 30 kV (contact)
IEC 61000-4-5; tp = 8/20
μ
s 12 A, 200 W
Maximum voltage range
-0.5 ~ 5.5 V
Maximum recommended working frequency 10 MHz (differential)
Maximum readable pulse frequency
50 MHz
Termination resistor
220
Ω
(between ENC_x+ and ENC_x-).
Fail safe bias resistors
ENC_x+ (positive input) 1 k
Ω
to 5 V
ENC_x- (negative input) 1 k
Ω
to 2.5 V (equivalent)
The wiring of a single-ended encoder to the Everest XCR is shown next: