Everest XCR - Product Manual |
Product Description
INGENIA | 08/04/2019
11
Case temperature
Operation:
•
-40 ºC to +60 ºC at full current (Minimum power up temperature is -30
ºC)
•
+60 ºC to +85 ºC with derated current
For further information, see Thermal Specifications below.
Storage:
-40 ºC to +100 ºC
Maximum humidity
5% ~ 85% non-condensing
ESD and EMC immunity
ESD immunity IEC 61000-4-2: ± 30 kV contact discharge , ± 30 kV air
discharge
EFT immunity IEC 61000-4-4: > 40 A
Surge immunity: IEC 61000-4-5 IPPM > 8 A
Mechanical specifications
Dimensions
42.1 mm x 29.1 mm x 23.1 mm
Dimensions include mating connectors
Weight
38 gr
Certifications
Certification
CE, RoHS
STO SIL3 (certification pending)
Environmental Specifications
IEC 60068-2-1: 2007-03 - Cold (Operational) test
IEC 60068-2-2: 2007-07 - Dry heat (Operational) test
IEC 60068-2-78: 2012-10 - Damp heat, steady state (operational) test
IEC 60068-2-38: 2009-01 - Composite temperature / humidity cyclic
(operational) test