9.3. Power Supply and Motor Power
9.3.1. Single Power Supply
The Everest XCR can be powered from a single power supply.
9.3.2.
Dual Power Supply
For systems where it is necessary to keep communications alive, or keeping position information with incremental
sensors while power is off, the drive can be powered from a logic supply input on the I/O connector. There are no
special power supply sequencing requirements.
Powering the logic supply at a lower voltage than the power will reduce the standby loss by increasing the
efficiency of the main DC/DC converter.
The logic supply voltage is limited to 50 V due to connector limits and ESD protections, the recommended levels are
9 V, 12 V or 24 V.