61
Figure 7-41
Please refer to the following sheet for detailed information.
Parameter
Function
Event Type
Event type: There are four types. Local
input/network input/IPC external/IPC offline
alarm.
Local input alarm: The alarm signal system
detects from the alarm input port.
Network input alarm: It is the alarm signal from
the network.
IPC external alarm: It is the on-off alarm signal
from the front-end device and can activate the
local NVR.
IPC offline alarm: Once you select this item,
system can generate an alarm when the front-end
IPC disconnects with the local NVR.
Alarm in
Select corresponding alarm channel.
Enable
You need to draw a circle here so that system can
detect the alarm signal.
Type
There are two options: normal open and normal
close. NO becomes activated in low voltage, NC
becomes activated in high voltage.
Period
Alarm record function becomes activated in the
specified periods.
There are six periods in one day. Please draw a
circle to enable corresponding period.
Select date. If you do not select, current setup
applies to today only. You can select all week
column to apply to the whole week.
Click OK button, system goes back to alarm
setup interface, please click save button to exit.
Anti-dither
System only memorizes one event during the
anti-dither period. The value ranges from 0 to
15s.
Parameter
Function
Relay Out
Enable alarm activation function. You need to
select alarm output port so that system can
activate corresponding alarm device when an
alarm occurs.
For 6-ch alarm output port device, the 6
th
channel is the contro12V output.
Alarm
Latch
System can delay the alarm output for specified
time after alarm ended. The value ranges from
10 seconds to 300 seconds.
Record
Channel
System auto activates current channel to record
once an alarm occurs (working with alarm
activation function). Please note current device
shall be in auto record mode
Record
Latch
System can delay the record for specified time
after an alarm ended. The value ranges from 10s
to 300s.
Please draw a circle to enable email function.
System can send out email to alert you when an
alarm occurs and ends.
Screen
display
After enabled, alarm info will be prompted out
on the local output end. That is to say, the alarm
prompt will be displayed beside the channel
name on the local surveillance image.
Buzzer
Once you check the box here, the buzzer beeps
when an alarm occurred.
Tour
Display the selected video in local monitor
window. When alarm occurs, system can begin
one-window tour for the activated record
channel. Please set the tour time in the local end.
PTZ
activation
Here you can set PTZ movement when alarm
occurs. Such as go to preset x when there is an
alarm.
The PTZ configuration events include preset,
tour, and pattern.
Capture
You need to input capture channel number so
that system can backup snapshot file when an
alarm occurs.
Copy
It is a shortcut menu button. You can copy
current channel setup to one or more (all)
channels.
7.4.2.7 Detect
By analyzing video image, system will boot video detection alarm
when it senses the motion signal which meets the senility standard
that is previously set. See Figure 7-42.