![Infineon OPTIREG TLF30681QVS01 Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/infineon/optireg-tlf30681qvs01/optireg-tlf30681qvs01_manual_2055183080.webp)
Table 23
Operational states functional overview. (continued)
ACTIVE
FAULT
LOCKED
DISABLED
Block or function
VM2
on
RW
off
R
off
R
off
R
–
–
–
–
–
–
–
–
–
Window watchdog
on
RW
off
R
off
R
off
R
–
–
–
–
–
–
–
–
–
Microcontroller reset –
ROT
ACTIVE
R
"low"
R
"low"
R
"low"
R
Persistent registers
All registers
-
Event
registers
-
Event
registers
-
-
-
•
on: The function is automatically activated when entering the state . The Function may be configured via
SPI within the current state.
•
SEL: The function is operating as configured via SPI (during the mode transition or within the current
operation mode).
•
off: The function is automatically deactivated when entering the operation mode.
•
R: The state of the feature cannot be changed in the current operation mode.
•
RW: The state of the feature can be changed in the current operation mode.
•
"high": The signal is "high" in this operation mode.
•
"low": The signal is "low" in this operation mode.
•
ACTIVE: The reset signal may generate a reset event (edge) in this operation mode.
OPTIREG
™
PMIC TLF30681QVS01
Power management IC
State machine
Datasheet
80
Rev. 1.0
2020-04-08