Fault: no trigger during open window after initialization
Long Open Window
ROT
WDI
variable
immediately
1
2
3
4
FAULT!
Valid WWD triggering
Invalid WWD triggering
WWDSCMD
Closed Window
fixed
Long Open Window
5
Figure 17
Fault operation: No trigger in open window after initialization
1.
The initialization timeout usually finishes slightly before or at the same time as the long open window,
which skips the interrupt event. However, the missing valid triggering within the long open window can
still lead to an interrupt event after the long open window terminates, which increases the window
watchdog error counter by two.
2.
The initialization timer expires for the first time. As the window watchdog does not detect valid triggering
during ACTIVE state, it generates a soft reset: The device sets ROT to "low", while the output voltages of
the post regulators remain on.
3.
After the soft reset the pin ROT turns "high" after the power-on reset delay time
t
rd
. The window
watchdog opens a long open window, so the microcontroller gets the opportunity to trigger and
synchronize to the watchdog period.
4.
On valid triggering the window watchdog terminates the open window. The duration of the open window
depends on when the triggering occurs. Due to the valid WWD triggering the window watchdog starts a
closed window and it decrements the window watchdog error counter by 1.
5.
The subsequent closed window lasts for the time
t
WD,CW
. Triggering within this closed window is invalid
WWD triggering.
OPTIREG
™
PMIC TLF30681QVS01
Power management IC
Microcontroller interface and supervisory functions
Datasheet
72
Rev. 1.0
2020-04-08