7.5.2
Electrical characteristics window watchdog
Table 21
Electrical characteristics window watchdog
T
j
= -40°C to 150°C;
V
R1VSx
= 3.7 V to 35 V; all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Parameter
Symbol
Values
Unit
Note or condition Number
Min.
Typ.
Max.
Watchdog cycle time,
configuration option 0
t
WDCYC
9.5
10
10.5
µs
–
P_7.5.1.1
Watchdog cycle time,
configuration option 1
t
WDCYC
95
100
105
µs
–
P_7.5.1.2
Long open window time
t
LOW
570
600
630
ms
–
P_7.5.1.3
Watchdog input WDI
Watchdog sampling time
t
WDI_filter
380
400
420
µs
–
P_7.5.1.4
Valid input level "high"
V
WDI, high
0.7
–
–
V
IOVDD
V
WDI
increasing
P_7.5.1.5
Valid input level "low"
V
WDI, low
–
–
0.8
V
V
WDI
decreasing
P_7.5.1.6
Input hysteresis
V
WDI, hyst
–
0.06
–
V
IOVDD
–
P_7.5.1.7
Pull-down current
I
WDI
–
135
330
µA
–
P_7.5.1.8
Input capacitance
C
WDI
–
4
15
pF
P_7.5.1.9
7.6
Microcontroller programming mode
The device includes a feature to support programming of microcontroller firmware during production or in the
field by preventing periodic reset triggering during the initialization period.
The programming mode can be enabled by pulling the MPS pin "high". In programming mode the reset
generation to the microcontroller is modified, so that fault events of microcontroller monitoring features do not
generate a microcontroller reset. All other monitoring features that generate a microcontroller reset are still
active, see
. The interrupt generation and the state transitions are still active. However, the initialization
timer is disabled, so that the device can remain in ACTIVE state.
Operation of the internal state machine and the programming mode are independent, which allows the
transition to any state while the microcontroller programming mode is active. However, the microcontroller
monitoring is still active and will move the device into ACTIVE state. Therefore, leave the device in ACTIVE state
during a programming operation.
Voltage monitoring is active and generates the respective fault events. This may generate interrupts or move the
device into FAULT state depending on the nature of the event.
23
Not subject to production test, specified by design.
OPTIREG
™
PMIC TLF30681QVS01
Power management IC
Microcontroller interface and supervisory functions
Datasheet
76
Rev. 1.0