Page 24
INE SpA
Via Facca, 10 - 35013 Cittadella - PADOVA - ITALIA Tel. 049/9481111 - Fax 049/9400249 - [email protected] - www.ine.it
11 Lifting: indications and precautions
To lift the machine use
only the 4 holes
on
the base of the generator trolley PR8: take
care to ensure that the lifting cables form a
small angle with respect to the vertical. All
the movable parts on the machine –
e.g. gas
cylinder, generator-wire feeder extension, wire
feeder, torches, earth cables, etc.
– must be removed
to avoid uncontrollable falls of all or part of the lifted
load.
The machine is to be positioned on a solid
and stable surface or floor which is adequate
to the machine’s weight. The maximum
inclination allowed is of 10°.
12 Set-up
The safety rules reported in the preceding sections
should be carefully followed when setting up the
machine, i.e. when connecting the power source to its
wire feeder by means of the corresponding cable and
when connecting the mains input cable to the mains
supply.
Connect the power cable to a socket with an adequate
current supply and insert the
delayed line fuses
with
an adequate rated value, as specified in the table of
TECHNICAL DATA (page 92).
Make sure that the
yellow-green
wire, which is the
earth wire, is properly connected to the ground (this will
protect the user).
To start up the machine follow these steps:
•
Place the unit so that the vents are clear of any
obstruction to ventilation air. Keep it in a dry place
and at a distance of at least 0.5 m from walls, shields
or anything.
In case of TIG welding:
•
Connect the gas hose between the gas cylinder
(equipped with flow meter and pressure reducer)
and the socket ‘G1’ on the power source rear panel;
connect the TIG torch to the socket ‘A2’ on the front
panel. Connect the torch gas hose and the torch
trigger wire to the corresponding ’G2’ and ‘C2’
connectors on the front panel.
•
Connect the work return lead to the socket ‘A1’ on
the power source and clamp it to a clean area of the
workpiece.
In the case of MMA welding:
•
Connect the electrode holder to its socket (positive
‘A1’ or negative ‘A2’), as requested by the type of
electrode.
•
Connect the work return lead to the free socket on
the power source and clamp it to a clean area of the
workpiece.
H
SI
L
G
N
E
MAX
15°
A2
G2
C2
A1
G1
C3
optional
Содержание SKYLINE HFP3000
Страница 96: ......