Industrex M43ic / M43icN
page 40
01/2013 TK
Problem
11. No fresh water supply
12. Circulation pump don´t
work
13. Level in water tank too
high, watertank
overflows
14. Level in Developer-
or Fixertank too low.
Possible cause
correction
A) Water tap is closed
B) Watervalve is blocked or
faulty
C) main board defective
D) Fuse is faulty
A) Pump wheel is blocked by
dirt
B) Fuse faulty
A) Water drain/overflow
blocked
B) Worse water drain
installation
A) Tank leaks
B) Too low replenishment
rate or too long anti ox.
cycle
C) Replenishment container
empty
D) Replenishment pump
faulty
E) Drain taps leaks
A) Open water tap
B) Clean the small filter in the
valve, or exchange it
C) Call service/change main
board
D) Change fuse F8
A) Clean the pump wheel and
make shure easy running
B) Change fuse F7
A) Clean the water tank and
clean the overflow and the
water drain.
B) change the water drain
installation
A) Seal the tank leak/call
service
B) Increase the replenishment
rate or decrease the Anti ox
cycle time
C) Fill up the replenishment
containers
D) Clean the replenishment
pump or exchange it
E) Close drain taps/
replace drain taps
Содержание M43ic
Страница 1: ...INSTRUCTION MANUAL 04 2011 TK NDT FILM PROCESSOR Industrex M43ic M43icN AT800 v2 8r09p and up ...
Страница 3: ...Input speed DEV time Cycle time KODAKIndustrexM43ic Industrex M43ic M43icN ...
Страница 49: ...page 43 01 2013 TK Industrex M43ic M43icN NOTES ...
Страница 50: ...page 44 01 2013 TK Industrex M43ic M43icN NOTES ...
Страница 51: ...page 45 01 2013 TK Industrex M43ic M43icN NOTES ...