BOBCAT HD-SDI
Hardware User’s Manual
Imperx, Inc.
Rev. 1.4
6421 Congress Ave.
6/2/2014
Boca Raton, FL 33487
+1 (561) 989-0006
146 of 175
A.0
ABBREVIATIONS
RW
– read/write,
RO
– read only,
WO
– write only
MAX_HRZ_SZE, MIN_HRZ_SZE
– Max. and Min. horizontal image size – camera
dependent
MAX_VER_SZE, MIN_VER_SZE
– Max. and Min. vertical image size – camera
dependent
LIN_TIM_MIN
–
Minimum Line time – camera dependent
FRM_TIM_MIN
– Minimum Frame time – camera dependent
FRM_TIM_ACT
– Actual Current Frame time - variable
FRR_EXP_MIN
– Minimum Exposure time – camera dependent
A.1
SAVING AND RESTORING REGISTERS
Address
Register Name
Type
Usage
MIN Value
MAX Value
0x6000 Boot From
RW
00 - Factory,
01 - User 1,
10 - User 2
0x00000000
0x00000002
0x6060 Load From Factory
WO
Command
0x00000000
0x6064 Load From User1
WO
Command
0x00000000
0x6068 Load From User2
WO
Command
0x00000000
0x606C Load MFG Default Gain
WO
Command
0x00000000
0x6074 Save to User1
WO
Command
0x00000000
0x6078 Save to User2
WO
Command
0x00000000
0x0604 RS-232 Baud Rate Selector RW
<BAUD Value>
0x00000000 0x00000004
A.2
CAMERA INFORMATION REGISTERS
Address
Register Name
Type
Value
0x6004 Firmware Revision
RO
<Firmware Revision>
0x6008 Firmware Build Number
RO
<Firmware Build Number>
0xE004
I/O Firmware Revision
RO
<I/O Firmware Revision>
0xE008
I/O Firmware Build Number
RO
<I/O Firmware Build Number>
0x600C Test Register
RW
0x76543210
0x601C Soft Reset
WO
0xDEDBEEF
0x6080 Horizontal Frame Size
RO
<MAX_HRZ_SZE, MIN_HRZ_SZE>