BOBCAT HD-SDI
Hardware User’s Manual
Imperx, Inc.
Rev. 1.4
6421 Congress Ave.
6/2/2014
Boca Raton, FL 33487
+1 (561) 989-0006
112 of 175
: 0xFF – maximum speed (GUI, SPD)
Data (31:8)
: N/A
4.5.1.5.
Focus Travel Distance
This register sets the number of motor control pulses to control focus travel
distance.
Address
: 0x041C
Data (11:0)
: 0x001 – min travel distance (GUI,Near)
: 0xFFF – max travel distance (GUI,Far)
Data (23:16)
: 0x01 – Focus Near (slider/window #), (GUI, <)
: 0x02 – Focus Far (slider/window #), (GUI, >)
: 0x04 – Focus Near (full, 0xFFF pulses), (GUI, <<)
: 0x08 – Focus Far (full, 0xFFF pulses), (GUI, >>)
: 0x10 – Focus Stop
Data (15:12)
: N/A
Data (31:24)
: N/A
4.5.1.6.
Focus Speed
This register sets the distance between pulses to control focus speed.
Address
: 0x0420
Data (7:0)
: 0x01 – minimum speed (GUI, SPD)
: 0xFF – maximum speed (GUI, SPD)
Data (31:8)
: N/A
4.5.1.7.
Iris Travel Distance
This register sets the number of motor control pulses to control iris travel
distance.
Address
: 0x0414
Data (11:0)
: 0x001 – min travel distance (GUI slider, Close)
: 0xFFF – max travel distance (GUI slider, Open)
Data (23:16)
: 0x01 – Iris Close (slider/window #), (GUI, <)
: 0x02 – Iris Open (slider/window #), (GUI, >)
: 0x04 – Iris Close (full, 0xFFF pulses), (GUI, <<)
: 0x08 – Iris Open (full, 0xFFF pulses), (GUI, >>)
: 0x10 – Iris Stop
Data (15:12)
: N/A
Data (31:24)
: N/A