Chapter 7 Usage of Various Functions
7-
ేై
2) Functional Specification
Item
Specification
No. of output
1 point
Output type
Pulse
Output velocity
Max 2Kpps, Min 50pps
Output pulse
0 ~ 2147483647
Execution type of the increasing/decreasing velocity
Designation of acceleration
Type of the direction designation
Right/opposite direction pulse output
Load power supply
DC 12V/24V
Usable range of the load power supply
DC10.2 ~ 26.4V
Maximum load current
150mA
Initiative electric current
Less than 0.4A, 10ms
Maximum power dropdown under On
Less than DC 0.5V
Electric current leakage under Off
Less than 0.1mA
On delayed time
Less than 1ms
Off delayed time
Less than 1ms
1) Several points can be used for the pulse output point if they are not output at the same time. Thus it is
possible that right direction pulse is output as P040, opposite direction pulse is output as P041.
Remark
Содержание K7 Series
Страница 1: ...User s Manual Programmable Logic Controller IMO K7 IMO Precision Controls...
Страница 21: ...Chapter 4 Names of Parts 4 4 1 2 30 points base unit 4 1 3 40 points base unit 4 1 4 60 points base unit...
Страница 57: ...Chapter 6 Input and Output Modules 6 3 40 point base unit 4 60 point base unit DC24V DC24V DC24V DC24V...
Страница 166: ...Chapter8 Communication Function 8 43 Set parameters like the following table and click OK button Program...
Страница 189: ...Chapter 8 Communication Function 8 66 You can see the framelist which is designated Click OK button...
Страница 234: ......