![ILX Lightwave LDC-3908 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/ilx-lightwave/ldc-3908/ldc-3908_user-manual_2044768051.webp)
C O M M A N D R E F E R E N C E
LDC-3908 Mainframe Command Reference
36
LDC-3908
C H A P T E R
4
!
The RADix? query allows the programmer to determine which radix type for status, condition, and
event query response data is currently selected. Decimal, binary, octal, and hexadecimal are
allowed.
Parameters
None. The response will be character data. A response of DEC means decimal, BIN means binary,
HEX means hexadecimal, and OCT means octal.
Notes
DEC is the default type. The LDC-3908 Laser Diode Controller defaults to this radix at power-up.
The RADix command is used to select the desired radix. Once it is changed, the new radix will
remain in effect until the power is shut off or a new RADix command is issued.
Examples
“RAD?” -response: Dec, means the selected radix is decimal.
"rad?" -response: Hex, means the selected radix is hexadecimal.
"RADIX?" -response: Oct, means the selected radix is octal.
The SCRoll command enables or disables the auto-scrolling feature of the ALL status screen.
Parameters
A Boolean value, 0 = FALSE (disabled), non-zero = TRUE (enabled).
Notes
This command affects the Status screen only.
The scrolling rate is not adjustable.
When the auto-scrolling feature is enabled it is in effect until it is disabled or the LDC-3908 is
powered off.
Examples
“Scr 1" -action: Enables the auto-scrolling feature of the Status screen.
"SCROL 0" -action: Disables the auto-scrolling feature of the Status screen.
The SCRoll? query allows the programmer to determine the status of the auto-scrolling feature for
the Status Menu.
Parameters
None. The response is an <nrf value>, 1 = TRUE (enabled), 0 = FALSE (disabled).
Notes
In local operation, the user must select the Status screen in order to determine if the auto-scrolling
feature is in use.
Examples
“Scroll?” -response: 1, means that auto-scrolling is enabled for the Status screen.
"SCR?" -response: 0, means that auto-scrolling is disabled for the Status screen.
The SECURE command allows the service technician access to the protected user data command,
*PUD, which is a common command. This data is normally changed only at the factory, and
therefore the SECURE command is not needed by the user.
RADix?
F
RONT
P
ANEL
R
EMOTE
SCRoll
F
RONT
P
ANEL
R
EMOTE
SCRoll?
F
RONT
P
ANEL
R
EMOTE
SECURE
F
RONT
P
ANEL
R
EMOTE
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание LDC-3908
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 7: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 9: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 11: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 53: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...