O P E R A T I O N S
Applying Power to the Laser Diode Controller
03_02
LDC-3908
9
C H A P T E R
2
!
Adjust Knob
When the cursor in a menu is positioned on a parameter which can be adjusted, the Adjust Knob
can be used to increase or decrease the parameter values. When the Adjust Knob is turned, the
new values are updated automatically. The Adjust Knob input may be disabled under the System
Configuration menu.
INC/DEC Keys
The Adjust INC and DEC keys also can be used to adjust values on any of the screens where a
numeric value is required. Holding down either of the keys will increase or decrease the number via
a simple time-based acceleration algorithm. When the keys are pressed, the new values are
updated automatically.
Applying Power to the Laser Diode Controller
To turn on the LDC-3908, push the button in the Power section of the front panel to change the
setting from zero (0) to one (1). This action will initiate the Power On Sequence. If the LDC-3908
does not appear to turn on, verify that it is connected to line power. If line power is not the problem,
remove the power cord and check the line power fuse.
The Power On Sequence
When power is applied to the LDC-3908, the following takes place: For about six seconds the
initialization screen is displayed, showing the company name and logo, the name of instrument,
and firmware version (in the lower left-hand corner of the screen). During this time, a self-test is
performed to ensure that the mainframe processor is communicating with the processor(s) of any
module(s) connected to the mainframe and also is identifying which module model is present. After
this test, the instrument is ready to operate and is configured to the state it was in when the power
was last shut off.
Figure 2.3
Initialization Menu
The Power On State
As described above, the instrument will be configured to the state it was in when power was last
shut off and according to the type of module in each bay (500 mA, 1A,1.5A combination module or
other modules). You can choose to clear the last saved instrument state by recalling the default
values. These values are stored in BINS which you can use to save or recall instrument
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание LDC-3908
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 7: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 9: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 11: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 53: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...