SmartPLC SafeLine AC4S with fieldbus interfaces
197
>
Input parameter
43017
Parameter
Data type
Description
Possible values
Enable
BOOL
FB activation
FALSE
FB is deactivated.
TRUE
FB is activated.
FB_Type
INT
ID of the function block (is
assigned by the programmer)
0x3D6B
SF_Antivalent
0x5096
SF_EDM
0x50A9
SF_EmergencyStop
0x5151
SF_EnableSwitch
0x516E
SF_Equivalent
0x56DD
SF_ESPE
0x56E2
SF_GuardLocking
0x571A
SF_GuardMonitoring
0x5725
SF_ModeSelector
0x5A03
SF_MutingPar
0x5A3C
SF_MutingPar_2Sensor
0x5BC4
SF_MutingSeq
0x5BFB
SF_OutControl
0x5C48
SF_SafetyRequest
0x5C77
SF_TestableSafetySensor
0x5D8F
SF_TwoHandControlTypeII
0x5DB0
SF_TwoHandControlTypeIII
FB_Number
INT
Instance number of the function
block (is assigned by the
programmer)
DiagCode
INT
Diagnostic code of the safety
PLCopen function block
→ Operating instructions safety PLCopen library in
CODESYS
The diagnostic code of the safety PLCopen FBs are of data type WORD.
>
Output parameters
43074
Parameter
Data type
Description
Possible values
Ready
BOOL
Status of the transmission of the
diagnostic code
FALSE
At present no transmission request
TRUE
Transmission of the diagnostic code
successfully completed
Error
BOOL
Error indication
FALSE
No error occurred during FB
processing
TRUE
Error occurred during FB processing;
transmission of the diagnostic code
failed