background image

eWON4002™

Ethernet Gateway

Remote Access Server (RAS)

Programmable Industrial Router (PIR)

Datalogger

Integrated Input/Output

3 serial Ports

INSTALLATION GUIDE

Rev. 2.04 - 

3/18/05

Cool

Internet    

Telecontrol

Solutions

Содержание eWON4002

Страница 1: ...N4002 Ethernet Gateway Remote Access Server RAS Programmable Industrial Router PIR Datalogger Integrated Input Output 3 serial Ports INSTALLATION GUIDE Rev 2 04 3 18 05 Cool Internet Telecontrol Solutions ...

Страница 2: ...ormation and versions 7 3 5 Mechanical outline 7 3 6 Mounting and environmental conditions 8 3 7 Preparing the installation 9 3 8 Specifications for external power supply selection 9 3 8 1 Auto fuse 9 4 Front panel control LEDs 10 5 Communication interfaces and I Os 11 5 1 Ethernet Port 11 5 2 Embedded PSTN Modem 11 5 3 Embedded GSM GPRS Modem 11 5 3 1 Recommendations for the GSM GPRS antenna 12 5...

Страница 3: ...23 9 Appendix Pinouts and connections 24 9 1 Power Supply 24 9 2 Ethernet 25 9 2 1 Direct connection 25 9 2 2 Connection over hub router 26 9 3 RJ45 connector 27 9 4 Input Outputs 28 9 4 1 DI DO connector 28 9 4 2 Analog Input 29 9 4 3 Relays output 30 9 4 4 Digital input 31 9 5 Serial Ports 32 9 5 1 Pinout serial ports 1 and 3 according to mode 33 9 5 2 Pinout serial port 2 33 9 6 Unitelway Modbu...

Страница 4: ...Explorer FTP client SNMP Manager Mail Recipient TCP and thus to reduce significantly your costs implementation and ownership 1 2 General specification of the hardware platform Processor ARM clocked 75Mhz 8Mb SDRAM 8 Mb Flash Battery backed up Real Time Clock RTC with 10 years autonomy External power supply 12 24 VDC 20 1 Ethernet port 10 100Mb BaseTx 1 isolated configurable serial port RS232 RS422...

Страница 5: ...or text format by FTP or as an Email attachment 1 6 Typical applications Alarm management Sending alarms by network phone Email and or SMS Remote measurements loop back control and monitoring Local or remote Human Machine Interface SCADA Predictive and operational maintenance Diagnosis and machinery status control Stock and vessel level monitoring Process and machinery activity logs Commissioning ...

Страница 6: ...s 1 8 External accessories External accessories available for the eWON4002 platform Table 2 Available external accessories Type Description Part Number eWON4002 Ethernet EW42201 eWON4002 PSTN33 PSTN modem EW42202 eWON4002 GSM GPRS GSM GPRS modem EW42205 Description Part Number Starter Kit Eth cables 1 straight 1 crossed CDROM EW40901 Antenna GSM GPRS dual band fixing by screw EW40902 Antenna adapt...

Страница 7: ...nd accessories Hardware specifications conformity to standards Installation recommendations and connectors pinout Step by step tutorial to establish first communications and make the IP configuration Exists for the following platforms eWON500 eWON2001 eWON4001 eWON4002 eWON1002 2 Software Getting Started 30pp Manual to start using the basic functions of the eWON software Covers most usual applicat...

Страница 8: ...ront view Figure 2 Housing bottom view Status leds Ethernet port 10 100 BaseTx Phone line Reset button Configurable serial port 1 Serial port 2 Din rail latch Configurable serial port 3 Power supply 12 24 VDC Digital I O connector Analog input connector Relay connector Serial port 3 dip switch Front Back ...

Страница 9: ...or more details See Equipment information and versions on page 7 3 3 Applicable directives standards and compliance 93 68 EEC European directive for CE mark 73 23 EEC European directive for the safety of low voltage equipment LVD Applicable standard is EN60950 A1 A4 A11 89 336 EEC amended by 92 31 EEC European directives for the electromagnetic compatibility EMC Applicable standards EN55022 94 A1 ...

Страница 10: ...hecked via a web browser on the eWON server see Communicating with the eWON on page 20 Once logged onto the eWON clicking on the eWON logo shows these revisions Figure 4 eWON info page details 3 5 Mechanical outline Figure 5 Mechanical outline IP Address Software version Serial Number System Info I O Modem free memory 106 mm 51 mm 120 mm ...

Страница 11: ...ection grade It is therefore not suited for outdoor mounting The design of the unit is such that it has to be integrated in an enclosed electrical cabinet protected from excessive heat humidity and dust The eWON4002 is complying to the CE marking requirements regarding electromagnetic compatibility EMC within an industrial environment The normal mounting position is wall mounted on DIN rail EN 500...

Страница 12: ...ly is not part of the delivery The data given below is intended to allow correct selection of the external power supply Table 4 Specification for external power supply selection Properly ground the unit with the earth screw at the bottom of the unit This is a must to ensure the security and the electromagnetic compatibility EMC of the device 3 8 1 Auto fuse An auto fuse placed just after at the po...

Страница 13: ...X LINK green ON Ethernet connected DI Input green ON logic 1 USER bicolor Hardware status flashing green normal state life 20 sec after power ON Other modes see Resets MODEM green ON DCD connected line PSTN and GSM D1 to D8 Digital Input leds RL1 and RL2 Relays leds SER2 and SER3 green Serial ports 2 and 3 Flashing activity RX DO Output green ON logic 1 ACT green Flashing transmitting Ethernet pac...

Страница 14: ...n 1 5 kV Pinout RJ45 connector See label and appendix RJ45 connector on page 27 Table 5 Ethernet port specification Specification Value Max baud rate V34 33 600 bps Compliant to standards 47 CFR part 68 USA CTR 21 EUR Approved by TÜV Rheinland USA Certificate number AU7MD01BMC56 Pinout phone line connector See label and appendix PSTN phone line connector on page 35 Table 6 PSTN modem specification...

Страница 15: ...on Specification Value Description GSM DCS gain GSM antenna Dual band 900 1800 MHz Gain dB 2 dB 900 MHz 0 dB 1800 MHz Max antenna cable length recommended 5m Antenna cable termination required to be compatible with the eWON SMA M Warning adapter SMA M FME M to be inserted if antenna has FME F termination available as spare Table 8 Recommendations for GSM GPRS antenna Eject SIM card button SMA ante...

Страница 16: ...in the table below note please don t forget that switch 1 is the most right one on the dip switch panel that matches serial port 1 the dip switch panel stands at the bottom right from the eWON s left face just beside the serial port 1 connector which stands at the bottom left from the eWON s front face Figure 9 Serial port 1 connector and dip switch Specification Value Physical modes configurable ...

Страница 17: ...yp 680 Ohms and termination typ 120 Ohms resistors This configuration applies only to RS4xx lines conforming to good practices 5 4 2 Serial port 2 Positions Mode RS232 RS422 RS485 WITHOUT polarisation and termination resistors RS422 RS485 WITH polarisation and termination resistors Table 10 Serial mode configuration switches Specification Value Physical mode Full RS232 Normal isolation NOT ISOLATE...

Страница 18: ...ftmost switch on the dip switch panel that matches serial port 3 this dip switch panel stands at the right part from the eWON s bottom face below the serial port 3 connector which stands at the bottom right from the eWON s front face just below serial port 2 Figure 10 Serial port 3 connector and dip switch Specification Value Physical modes configurable RS232 RS485 RS422 Normal isolation NOT ISOLA...

Страница 19: ...DI connector on the eWON s top face and 1 on the Input Output connector DIDO that stands on the eWON s bottom face Positions Mode RS232 RS422 RS485 WITHOUT polarisation and termination resistors RS422 RS485 WITH polarisation and termination resistors Table 13 Serial mode configuration switches Specification Value Type 24 VDC isolated Digital Input sink type Input voltage range 0 to 24 VDC Input vo...

Страница 20: ...ansistor used is of open collector type with pre drive This means the relay power supply has to be supplied from an external source to the pre drive electronics The diagram below shows the external wiring needed for correct operation of the Digital Output A relay has been chosen for this sample application but any load within the specifications can be used instead Warning note that this is a sink ...

Страница 21: ...witch located above the Analog Inputs connector rear switch Figure 12 Rear switch panel and label the label stands on the left side from the eWON To configure a channel to voltage input place the matching switch to OFF To configure a channel to current input place the matching switch to ON Specification Value Number of outputs 2 Type of output SPST NO relays Single Pole Single Throw Normally Open ...

Страница 22: ...nts 1 Resolution 12 bits 5 mV Precision 0 50 Voltage input impedence 300 kOhm Overvoltage protection 12VDC automatic fuse Table 16 Standard Analog Inputs Voltage input specification Specification Value Input range 0 to 20 mA Number of inputs 4 Common points 1 Resolution 12 bits 10 µA Precision 0 50 Current input impedence 220 Ohm 1 Max current 25 mA Table 17 Standard Analog Inputs Current input sp...

Страница 23: ...uration System Setup Communication DialUp PPP 6 2 By phone line or GSM 6 2 1 Under Windows 98 NT and 2000 1 Open the root folder Dial up Networking 2 Click on the icon Make new connection 3 Give a name to this connection 4 Select a local modem from the list and click Next 5 Introduce the phone number and the login adm and password adm of your eWON or the login password you have created and click N...

Страница 24: ...ectory and also under Start and Connect to as well as on your desktop if you selected the relevant option Create icon on desktop 10 You can now make a connection either by using the currently open window or later on by using one of the available paths Start menu or desktop icon 11 Wait until the modems are synchronized and that your PPP authentication has been accepted 12 Launch your Internet navi...

Страница 25: ...arning normally you cannot communicate with a device for which you don t know the IP parameters Therefore there is a special tool called eWONCfg you can download from the eWON Internet site http www ewon biz Start this application once you have connected your eWON to the network The application will scan the whole network and will identify all eWONs that are connected including their IP parameters...

Страница 26: ...ex factory configuration default config Full hardware auto test with result shown by the USER LED Warning you should not reset your eWON unless you have been told to do so by someone of our technical support The concerned files differs depending on reset type are totally lost and unrecoverable after being formatted You generate this second level reset by pressing and maintaining the reset button d...

Страница 27: ...supply mating female connector included Power supply mating female connector included Power supply connector pinout Manufacturer Phoenix Contact GmbH http www phoenixcontact com Part Number MVSTBW2 5 4 STF 5 08 Pin Description 1 Ground 2 Positive Table 19 Power supply connector pinout Pin 2 Pin 1 Power supply connector ...

Страница 28: ...different cables straight or crossed These cables have 8 copper conductors and are known as UTP Class 5 with RJ45 terminations at both ends These cables are availbale as spare parts see External accessories on page 3 The type of cable straight or crossed depends on the equipment the eWON will be connected to The most current cases are the direct connection with a PC crossed and the connection thro...

Страница 29: ...7 and 8 do not have to be connected The following picture shows the twisted pair connections Figure 15 Crossed cable cabling 9 2 2 Connection over hub router If the eWON is connected to a hub it has to be connected like any other device with a straight cable Again the wiring is as shown on the following picture and care should be taken to keep the RX and TX signals on twisted pairs TX pin3 TX pin6...

Страница 30: ...tion Guide page 27 of 35 ver 2 04 9 3 RJ45 connector The RJ45 connector has got the following pins numbering as it can be seen on the following picture showing it from different angles Figure 16 RJ 45 connector cabling ...

Страница 31: ...nout Table 21 Digital Input Output connector pinout Manufacturer Sauro http www sauro net Part Number CTF050VT Pin REF Description 1 DO_GND Output digital signal 0V ground connected to the emitter of the transistor 2 DO_OC Output digital signal connected to the collector of the transistor 3 DO_VDC Common of the external predrive power supply between 12 et 24 VDC 4 DI_GND Ground of the input isolat...

Страница 32: ...connector pinout Manufacturer Phoenix http www phoenixcontact com Part Number MVSTBW2 5 9 STF 5 08 Pin REF Description 1 AGND Analog Ground 2 AI4 Analog Input 4 3 AI3 Analog Input 3 4 AI2 Analog Input 1 5 AI1 Input digital signal 6 RTD1 Negative pole of RTD1 7 RTD1 Positive pole of RTD1 8 RTD2 Negative pole of RTD2 9 RTD2 Positive pole of RTD2 Table 23 Analog Input connector pinout Analog Input co...

Страница 33: ...r included Relays output connector pinout Manufacturer Phoenix http www phoenixcontact com Part Number MVSTBW2 5 4 STF 5 08 Table 24 Relays Output connector references Pin REF Description 1 RL1 a Relay 1 pole a 2 RL1 b Relay 1 pole b 3 RL2 a Relay 2 pole a 4 RL2 b Relay 2 pole b Table 25 Relays Output connector pinout RL1 RL2 Relay connector ...

Страница 34: ...om Part Number MVSTBW2 5 10 STF 5 08 Figure 21 Digital Input connector references Pin REF Description 1 ISOGND Isolated ground 2 DI1 Digital Input 1 3 DI2 Digital Input 2 4 DI3 Digital Input 3 5 DI4 Digital Input 4 6 DI5 Digital Input 5 7 DI6 Digital Input 6 8 DI7 Digital Input 7 9 DI8 Digital Input 8 10 ISOGND Isolated ground Table 26 Digital Input connector pinout DI8 DI1 Digital Input connector...

Страница 35: ...eWON4002 Installation Guide page 32 of 35 ver 2 04 9 5 Serial Ports Figure 22 Serial ports connectors Type Female DB9 with 4 40 blocking screws Serial port 2 Serial port 3 Serial port 1 ...

Страница 36: ...rts 1 and 3 according to mode 9 5 2 Pinout serial port 2 Pin RS232 RS485 RS422 1 2 RXD RX 3 TXD A TX 4 5 GND GND GND 6 7 RTS RX 8 CTS B TX 9 Table 27 Serial ports 1 and 3 pinout Pin RS232 1 DCD 2 RXD 3 TXD 4 DTR 5 COM GND 6 DSR 7 RTS 8 CTS 9 RI Table 28 Serial port 2 pinout ...

Страница 37: ...der PLCs It has a SUBD9 connector at the eWON side and a MiniDIN connector at the PLC side D A is connected to B and D B is connected to A MiniDIN PIN Schneider Signal Name eWON Signal Name eWON SUBDB9 connector 1 D B A DB9 pin 3 A 2 D A B DB9 pin 8 B 3 4 5 6 7 GND GND DB9 pin 5 GND 8 Connector shield Table 29 MiniDin and SubDB9 connectors pinout ...

Страница 38: ...phone line connector PSTN phone line mating male connector not included PSTN phone line mating male connector pinout Type RJ11 type 6P2C without shield Figure 24 PSTN phone line mating male connector type Pin Description 1 2 3 TIP 4 RING 5 6 Table 30 PSTN connector pinout PSTN phone line connector ...

Отзывы: