The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using it for any purpose other than the use of the products or the
execution of the project to which it refers, and from communicating it to third parties without Automatic Systems’ prior written agreement. Document subject to change without notice.
BL3x-MT-EN-08
page
9/59
2.4.
General conditions of use
•
Your rising barrier type BL32/BL33 has been designed to operate in any kind of climatic environment, from
-35°C to +50°C (thanks to integrated heating resistance), with up to 95% of relative humidity.
2.5. Emergency
operation
•
The following instructions are to be given to the installation supervisor.
2.5.1. Opening or closing in case of power failure
--
Insert the emergency crank handle (
1:10
) into the crank hole (+ refer to "safety warnings" chapter!).
A safety device automatically switches off the power supply, thus eliminating any risk of accident in
case the power supply returns.
--
Turn the crank clockwise to open the barrier and counter-clockwise to close the barrier.
--
When the arm is in the horizontal or vertical position, keep turning the crank to lock the barrier
mechanically.