Reader B Hold
Check why the Reader B command is being sustained on the
control board connector block
Position
Fail
The type of sensor selected is “
Analogue Sensor
” (“QUICK
START
”
►
menu “
Positioning
"); nevertheless, the obstacle still
has to be activated (
►
“
Activate Motor
?”
►
OK).
Counter
CR
•
The reader counter (see the “OPTIONS” menu
X
“Counter CR”) is greater than zero.
•
Or the timing for no passage is other than zero (see
the "TIMING" menu
X
"No Passage").
Open Status
Cases when the obstacle is prevented from opening during a
request to open.
OK
Normal
opening.
Lock CL Hold
Check why the Lock CL command is being sustained on the
control board connector block.
Lock Close LCD
The
“
Test Mode
” parameter of the “
TEST
” menu is not set to
“
Deactivated
”.
Delay Befor OP
Wait for the time programmed under the “
Delay Bef.
OP under
the “
TIMING
” menu to elapse.
Stop Cmd Hold
•
Check why the close order is being sustained on the
control board connector block.
•
Check whether the “Stop CMD" parameter is
programmed correctly (“Options” menu).
Arm ELV Locked
•
Check whether the detector of the unlocking of the
electrically locking (ELV) tip is functioning properly.
•
Check whether the “Arm" parameter in the
“OPTIONS” menu is programmed correctly.
Arm ELV Detect
Check whether the detector sensing the presence of the
arm is functioning properly on the control board connector
block.
Position
Fail
The type of sensor selected is “
Analog. Sensor
” (“QUICK
START
” menu
►
“
Positioning
"); nevertheless, the obstacle still
has to be activated (
►
“
Activate Motor
?”
►
OK).
Counter 1
0 to 99,000,000
(0 by default)
Total number of manoeuvres executed by the obstacle since it
was first put into service.
Counter 2
0 to 99,000,000
(0 by default)
Representation of counter 1, with the possibility of resetting it to
zero.
Reset counter 2
Counter 2 reset to zero.
OFF (by default)
No
resetting.
ON
Request to reset to zero.
Done
Message is displayed for 1 second when the counter has been
reset to zero.