The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using it for any purpose other than the use of the products or the
execution of the project to which it refers, and from communicating it to third parties without Automatic Systems’ prior written agreement. Document subject to change without notice.
BL3x-MT-EN-08
page
20/59
Curve BL46 SR
Change in the type of barrier: Selection of “curve BL46SR”
(“
Barrier Type
” parameter under the “
QUICK START
” menu).
Curve RSB 70&71
Change in the type of equipment: Selection of “curve RSB
70&71” (“
Barrier Type
” parameter under the “
QUICK START
”
menu).
Unlock BL4x Er
Only with “
locking of the arm
” option for BL4x. The inductive
sensor has not detected the unblocking of the lock within the 3
seconds following the open or close request: check whether the
locking pin is pressing on the locking clips, preventing them form
opening, or whether the sensor is defective.
Close Status
Cases when the obstacle is prevented from closing during a
close request:
OK
Normal closure.
PS1 Activated
PS2 Activated
PS3 Activated
PS4 Activated
A sensor (loop/cell) detects the presence or a cut in the
circuit. In the latter case:
•
Check whether the sensor is plugged into the
corresponding connector block and whether it is
functioning properly.
•
Check whether the sensor is properly connected.
•
Check whether the sensors are programmed correctly
(“SENSOR FUNCTION” menu).
Lock OP Hold
Check why the Lock Open command is being sustained on the
control board connector block.
Safe Arm Activ
Activation of the “Safety Arm" sensor (only with the
“rubber protection profile” option: rubber strip that detects
when the arm makes contact with a vehicle):
•
Check whether the arm safety sensor is functioning
properly.
•
Check whether the “Safety Arm" parameter is
programmed correctly (“Options” menu).
PWF Open Activ
Setting of the “
PWF Open Activ
” parameter of the “
OPTIONS
”
menu to “ON”, that is to say that during activation the obstacle
opens and waits for the activation of a close or lock-close
command.
Note
: the closure loops are not taken into account for closing in
this case.
Lock Open LCD
The “Test Mode” parameter of the “TEST” menu is not set to
“
Deactivated
”.
Delay Befor CL
Wait for the delay programmed under the “Delay Befor. CL”
parameter
under
the “TIMING” menu to elapse.
Open Cmd Hold
Check why the open command is being sustained on the control
board connector block.
Stop Cmd Hold
•
Check why the stop command is being sustained on
the control board connector block.
•
Check whether the “Stop Cmd" parameter is
programmed correctly (“Options” menu).
Reader A Hold
Check why the Reader A command is being sustained on the
control board connector block.