The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using it for any purpose other than the use of the products or the
execution of the project to which it refers, and from communicating it to third parties without Automatic Systems’ prior written agreement. Document subject to change without notice.
BL3x-MT-EN-08
page
54/59
INPUTS
Signals from outside that are received by the control board.
There is a green LED under every input pin, which indicates the status (ON/OFF) of the latter.
DI1, DI2, DI3, DI4 (cell)
: signal from the optional safety cells (see “connecting the presence sensors” below).
DI5 (Swing off sens./Lock)
:
1.
Swing off sensor
: for all machines except BL4x, signal emitted by the optional arm swing off detector
when it no longer detects the arm on the jaw. Also, configure the “
Arm Swing Off
” parameter in the
“
OPTIONS
” menu.
2.
Lock
: for BL4x, signal emitted by the arm locking device sensor, indicating the status of the lock (locked
or unlocked).
DI6 (reader A command):
order to open from the optional badge reader.
DI7 (stop command):
order to stop the movement of the obstacle immediately, emitted by a push-button box,
remote control, etc. Also, configure the “
Stop CMD
” parameter in the “
OPTIONS
” menu.
DI8 (open CMD)
: order to open the obstacle, emitted by a push-button box, remote control, reader, etc. Also,
configure the “
Exploitation
” parameter in the “
QUICK START
” menu.
DI9 (close CMD)
: order to close the obstacle, emitted by a push-button box, remote control, etc. Also, configure
the “
Exploitation
” parameter in the “
QUICK START
” menu.
DI10 (lock open CMD)
: order to keep the obstacle in the open position, emitted by an external interrupter.
DI11 (lock close CMD)
: order to keep the obstacle in the closed position, emitted by an external interrupter.
DI12 (Sw open)
: signal emitted by an opening limit-switch detector, when the obstacle reaches the limit switch.
DI13 (Sw close)
: signal emitted by a closing limit-switch detector, when the obstacle reaches the limit switch.
DI14 (crank limit switch)
: signal emitted by the presence detector of the crank used for manual operation of the
obstacle (only on some types of equipment). This indication allows for the motor command outputs (DO7 and
DO8) to be cut, in order for the obstacle not to become electronically activated while the crank is engaged
(safety).
If there is no detector on the equipment, connector blocks B4 and C4 must be bypassed.
AI1 (analogue sensor)
: analogue signal emitted by the analogue position sensor. The sensor must be activated
(“
Positioning
” parameter under the “
QUICK START
” menu).
OUTPUTS
Signals sent by the control board to external elements.
There is a red LED under every input pin, which indicates the status (ON/OFF) of the latter.
REL1-
and
REL1+
: 0 V and 24 VDC connectors of the relay from which the indication to transmit comes
(parameter is adjustable via the “
OUTPUT FUNCTION
” menu).
REL2-
and
REL2+
: 0 V and 24 VDC connectors of the relay from which the indication to transmit comes
(parameter is adjustable via the “
OUTPUT FUNCTION
” menu).
REL3-
and
REL3+
: 0 V and 24 VDC connectors of the relay from which the indication to transmit comes
(parameter is adjustable via the “
OUTPUT FUNCTION
” menu).
DO7 (rising motor)
: output of status 1 if the obstacle is opening or completely open.
DO8 (descending motor)
: output of status 1 if the obstacle is closing or completely closed.
(DO9 = Power relay 1)
DO10 PWM
and
DO11 PWM ("Pulse Width Modulation")
: power element commands, such as arm lighting or
flashing light (parameters adjustable via the “
OUTPUT FUNCTION
” menu: outputs 10 and 11).
AO1 (FI setting)
: analogue signal sent to the frequency inverter controlling the speed of the motor.
CONNECTORS FOR EXTERNAL ELEMENTS
24V
:
24 Volt DC connector.
GND
: 0 Volt connector.