Display of the last 100 events (use
►
the
▲
and keys to view
preceding events).
For the first two seconds, the event number (00 for the last event
recorded (= most recent), 01 for the preceding event, and so
on), as well as the date (year-month-day) and time (hours-
minutes-seconds) of creation are displayed.
In the next two seconds, the event description is displayed.
For example:
2 s
Log
00 060324 235034
On 24 March 2006 at 23 hours
(11 p.m.) 50 minutes and 34
seconds…
2 s
Log
Out Of Service
…the apparatus was put out of
service.
2 s
Log
01 060324 235034
View the preceding message
(01) using the
►▲
keys…
2 s
Log
Open Time Out
…we observe that it was put out
of service due to a time out
while opening.
Note
: If no error message is displayed when the machine fails,
refer to the Troubleshooting chapter.
Power
Up
Power was turned on.
Power
Down
Power was turned off.
Short
Circuit
Short circuit of the control board outputs (connector blocks). The
short circuit is declared and the equipment put Out of Service
only after 3 unsuccessful reactivation tries within the 2.5 seconds
following a voltage drop in the 24V power supply (this is to avoid
putting it out of service at inopportune moments, as for example
during a network changeover to an emergency generator).
If one of the outputs short circuits, all of them become inactive
and the control board must be powered up again for the outputs
to be reactivated.
Open Time Out
Time out during opening: the time allocated for opening was
exceeded ("TIMING" menu, “OpenTimeOut” parameter).
Close Time Out
Time out during closing: the time allocated for closing was
exceeded ("TIMING" menu, “CloseTimeOut” parameter).
Close
Retries
Allotted number of trials to close have been executed (as defined
in the “TIMING” menu).
Arm Swing Off
Arm detected out of its support jaw (see the “
Arm Swing Off
"
parameter in the “OPTIONS” menu).
If the message continues to be displayed after the arm is
rehinged, check the status of the “SW arm presence” sensor and
its fastening