2. RapidIO Ports > Packet Generation and Capture
CPS-1848 User Manual
61
June 2, 2014
Formal Status
This document is confidential and is subject to an NDA.
Integrated Device Technology
5. Read out maintenance
read response
0x100140
0x00006004
Enable read access to final buffer priority 1
queue.
0x100144
Read
0x0048BBAA
Bytes 0–3 of Maintenance Read Response
-
0x100140
Read
Check that SOP bit is set.
0x00006004
Enable read access to final buffer priority 1
queue.
-
0x100144
Read
0x2000FE00
Bytes 4–7 of Maintenance Read Response
-
0x100140
Read
Check that SOP and EOP bits are 0.
0x100140
0x00006004
Enable read access to final buffer priority 1
queue.
-
0x100144
Read
0x0000XXXX
Bytes 8–11 of Maintenance Read
Response, where XXXX is the most
significant 2 bytes of the link partners
Device Identity CAR
-
0x100140
Read
Check that SOP and EOP bits are 0.
0x00006004
Enable read access to final buffer priority 1
queue.
-
0x100144
Read
0xXXXX0000
Bytes 12–15 of Maintenance Read
Response, where XXXX is the least
significant 2 bytes of the link partners
Device Identity CAR.
-
0x100140
Read
Check that SOP and EOP bits are 0.
0x00006004
Enable read access to final buffer priority 1
queue.
-
0x100144
Read
0x0000XXXX
Bytes 16–19 of Maintenance Read
Response, where XXXX is the CRC for the
response packet.
-
0x100140
Read
Check that SOP is 0, and EOP bit is 1.
0x00006004
Enable read access to final buffer priority 1
queue.
Table 13: PGC Mode Example – Connectivity Test (Continued)
Step
Register
Offset
Value
Description