10. Registers > Special Error Registers
CPS-1848 User Manual
411
June 2, 2014
Formal Status
This document is confidential and is subject to an NDA.
Integrated Device Technology
10.18.4 Error Log Events Register
Register Name: LOG_EVENTS
Reset Value: 0x0000_0000
Register Offset: 0xFD002C
Bits
0
1
2
3
4
5
6
7
00:07
Reserved
08:15
Reserved
16:23
CNT
24:31
CNT
Bits
Name
Description
Type
Reset
Value
0:15
Reserved
Reserved
RO
0
16:31
CNT
Error log event count. If the counter reaches its maximum value
of 0xFFFF it will stop incrementing, and remain at its maximum
value until it is reset.
CNT is reset when the Error Manager is reset, or CNT_RESET is
set in the
.
RO
0