Notes
PES16T4AG2 User Manual
6 - 1
May 23, 2013
®
Chapter 6
Power Management
Introduction
Located in configuration space of each PCI-PCI bridge in the PES16T4AG2 is a power management
capability structure. The power management capability structure associated with a PCI-PCI bridge of a
downstream port only affects that port. Entering the D3
Hot
state allows the link associated with the bridge to
enter the L1 state.
–
The link associated with a port in the D3
Hot
state will attempt to transition into L1 link state irre-
spective of the link or power management state of any other switch port.
The power management capability structure associated with the upstream port (i.e., Port 0) affects the
entire device. When the upstream port enters a low power state and the PME_TO_Ack messages are
received, then the entire device is placed into a low power state. The PES16T4AG2 supports the following
device power management states: D0 Uninitialized, D0 Active, D3
Hot
, and D3
Cold
. A power management
state transition diagram for the states supported by the PES16T4AG2 is provided in Figure 6.1 and
described in Table 6.1.
Transitioning a port’s power management state from D3
hot
to D0
uninitialized
does not result in any logic
being reset or re-initialization of register values. Thus, the default value of the No Soft Reset
(NOSOFTRST) bit in the PCI Power Management Control and Status (PMCSR) register corresponds to the
functional context being maintained in the D3
hot
state.
Figure 6.1 PES16T4AG2 Power Management State Transition Diagram
D0
Uninitialized
D0
Active
D3
hot
Power-On Reset
D3
cold
Содержание 89HPES16T4AG2
Страница 8: ...IDT PES16T4AG2 User Manual 6 May 23 2013 Notes...
Страница 12: ...IDT Table of Contents PES16T4AG2 User Manual iv May 23 2013 Notes...
Страница 14: ...IDT List of Tables PES16T4AG2 User Manual vi May 23 2013 Notes...
Страница 16: ...IDT List of Figures PES16T4AG2 User Manual viii May 23 2013 Notes...
Страница 20: ...IDT Register List PES16T4AG2 User Manual xii May 23 2013 Notes...
Страница 72: ...IDT SMBus Interfaces PES16T4AG2 User Manual 5 20 May 23 2013 Notes...
Страница 76: ...IDT Power Management PES16T4AG2 User Manual 6 4 May 23 2013 Notes...
Страница 156: ...IDT Configuration Registers PES16T4AG2 User Manual 8 74 May 23 2013 Notes...