IDT Clocking, Reset and Initialization
PES16T4AG2 User Manual
2 - 8
May 23, 2013
Notes
When slot power is disabled by writing a one to the PCC bit, the corresponding downstream port reset
output is asserted and then slot power is disabled. The time between the assertion of the PxRSTN signal
and the negation of the PxPEP signal is controlled by the value in the Reset Negation to Slot Power
(RST2PWR) field in the HPCFGCTL register.
If at any point while a downstream port is not being reset (i.e., PxRSTN is negated) a power fault is
detected (i.e., PxPWRGDN is negated), then the corresponding port reset output is immediately asserted.
Since the PxPWRGDN signal is an I/O expander input, it may not be possible to meet a profile’s power level
invalid to reset asserted timing specification (i.e., PxPWRGDN to PxRSTN). Systems that require a shorter
time interval may implement this functionality external to the PES16T4AG2.