IDT Configuration Registers
PES16T4AG2 User Manual
8 - 72
May 23, 2013
Notes
ALRSTS - Autonomous Link Reliability Status (0x564)
ALRERT - Autonomous Link Reliability Error Rate Threshold (0x5680)
Bit
Field
Field
Name
Type
Default
Value
Description
0
ULD
RW1C
0x0
Sticky
Unreliable Link Detected.
This bit is set by hardware to indi-
cate that the Autonomous Link Reliability logic has detected an
unreliable link. This occurs when the rate of errors in the link
matches or exceeds the threshold value specified in the ALR-
ERT register (i.e., the ENCNT field in the ALRCNT register is
greater than or equal to the ERRT field in the ALRERT register).
This bit is only set when the EN bit in the ALRCTL register is
set.
Once set, this bit is never cleared by hardware.
31:1
Reserved
RO
0x0
Reserved field.
Bit
Field
Field
Name
Type
Default
Value
Description
7:0
ERRT
RW
0xFF
Sticky
Error Threshold.
The value in this field represents the mini-
mum number of errors that must be detected by the Autono-
mous Link Reliability Management logic in order to determine
link unreliability.
The value of 0x0 is ‘Reserved’. When 0x0 is programmed into
this field, the operation is undefined.
Please refer to section Autonomous Link Reliability Manage-
ment on page 3-6 for further details.
31:8
PERIOD
RW
0xFF_FFFF
Sticky
Monitoring Period.
The value in this field represents the time
window (in units of micro-seconds) in which a number of errors
equal to ERRT must be detected in order to determine link unre-
liability.
A value of 0x0 is ‘Reserved’. When 0x0 is programmed into this
field, the operation is undefined.
Please refer to section Autonomous Link Reliability Manage-
ment on page 3-6 for further details.
Содержание 89HPES16T4AG2
Страница 8: ...IDT PES16T4AG2 User Manual 6 May 23 2013 Notes...
Страница 12: ...IDT Table of Contents PES16T4AG2 User Manual iv May 23 2013 Notes...
Страница 14: ...IDT List of Tables PES16T4AG2 User Manual vi May 23 2013 Notes...
Страница 16: ...IDT List of Figures PES16T4AG2 User Manual viii May 23 2013 Notes...
Страница 20: ...IDT Register List PES16T4AG2 User Manual xii May 23 2013 Notes...
Страница 72: ...IDT SMBus Interfaces PES16T4AG2 User Manual 5 20 May 23 2013 Notes...
Страница 76: ...IDT Power Management PES16T4AG2 User Manual 6 4 May 23 2013 Notes...
Страница 156: ...IDT Configuration Registers PES16T4AG2 User Manual 8 74 May 23 2013 Notes...