4 Meter
11-66
WindO/I-NV4 User’s Manual
■
Data Format
■
Reference Device Address
Specifies the source word device for the data to display in the meter.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-68.
Data Type:
Selects the data type handled by the meter from the following.
UBIN16(W)
,
BIN16(I)
,
UBIN32(D)
,
BIN32(L)
,
BCD4(B)
,
BCD8(EB)
,
Float32(F)
For details, refer to Chapter 2 “1.1 Available Data” on page 2-1.
Minimum, Maximum: Specifies the minimum and maximum for the data.
(Data Type):
Selects the data type to use for the minimum and the maximum.
Value:
Uses a constant value.
Device Address: Uses a value of device address.
The minimum and maximum vary based on the selected data type. For details, refer to Chapter
2 “1.1 Available Data” on page 2-1.
The needle does not move past the left edge when the data value is the minimum or lower.
The needle stops at the right edge when the data value is the maximum or higher.
When
Device Address
is selected for (Data Type), the minimum and maximum can be
specified in the word device.
Click
to display the Tag Editor. For the device address configuration procedure, refer to
Chapter 2 “5.1 Device Address Settings” on page 2-68.
If the data displayed in the meter is invalid, 1 is written to System Area 2 Processing error bit (address
2, bit 5), and an error message is displayed. For details, refer to Chapter 4 “Processing error” on
page 4-32 and Chapter 36 “Processing error” on page 36-3.
An error occurs in the following states:
• The setting of
Minimum
,
Maximum
, or ranges are invalid, or the
Minimum
and
Maximum
are the
same values.
•
Data Type
is
BCD4(B)
,
BCD8(EB)
, or
Float32(F)
and the value cannot be expressed with the data
type selected for the read data
If an error occurs, only the flange is initially displayed. Then once the meter is displayed, it doesn't show an
update.
Содержание MICRO/I HG4G-CJT22 F-B Series
Страница 1: ...B 1701 11 User s Manual ...
Страница 26: ...Preface 25 WindO I NV4 User s Manual ...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic Font ANSI 1257 Cyrillic Font ANSI 1251 ...
Страница 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Страница 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Страница 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Страница 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Страница 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Страница 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Страница 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Страница 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Страница 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Страница 1286: ...4 Clear 24 26 WindO I NV4 User s Manual 4 Click Yes 5 Click Close This concludes clearing data ...
Страница 1288: ...4 Clear 24 28 WindO I NV4 User s Manual 6 Click Yes 7 Click Close This concludes clearing data on the external memory device ...
Страница 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Страница 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Страница 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Страница 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Страница 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Страница 1664: ...Index 12 WindO I NV4 User s Manual ...