3 Simulator
26-16
WindO/I-NV4 User’s Manual
■
(Breakpoint)
When the script is executed, it pauses when the processing reaches the breakpoint. You can check the value of the
device address at the time of stopping on the
Device Address List
.
The maximum number of breakpoints that can be configured for one script is 20.
■
(Script)
Displays the contents of the script selected in
Script List
.
Click inside the frame on the left side of (Script) to configure a breakpoint.
(red circle) is displayed, and the text on
the line configured the breakpoint is highlighted.
■
Device Address List
Displays the device addresses that are used in the script suspended at breakpoint and the values of them.
• The trigger condition for the script is satisfied and the script is executed, and then the processing of the
script is stopped when the configured breakpoint is reached.
• When you save the project, the setting of the breakpoint is also saved. However, the project data to be
downloaded does not include the setting of the breakpoint, so there is no breakpoint setting after
uploading the project.
Device Address:
Displays the device addresses used on the script.
next to
Comment
toggles between showing and hiding comments. When comments are
displayed, click to display a popup menu, then click
Comment
and select the check box.
Comment:
Displays comments on device addresses saved in Tag Editor. Comments are displayed only
after you click next to
Device Address
to display a popup menu, then click
Comment
and
select the check box.
Data Type:
Selects the data format of the displayed value. For details, refer to Chapter 2 “1.1 Available
Data” on page 2-1.
Words:
Specify the number of word devices (1 to 16) stored the display value. 2 single-byte characters
can be displayed by 1 word.
This option can only be configured
String(European)
,
String(Japanese)
,
String(Chinese)
,
String(Taiwanese)
,
String(Korean)
,
String(Central European)
,
String(Baltic)
or
String(Cyrillic)
is selected as Data Type.
The storage order for word device address data is set according to
Storage Method of
String Data
on the
System
tab in the
Project Settings
. For details, refer to Chapter 4
“Storage Method of String Data” on page 4-28.
Value:
Enables values of device addresses to be display and changed. The value range depends on
the data type. For details, refer to Chapter 2 “1.1 Available Data” on page 2-1.
UBIN16(W)
,
BIN16(I)
,
UBIN32(D)
,
BIN32(L)
,
BCD4(B)
,
BCD8(EB)
,
Float32(F)
:
Displays the current value of device address in decimal format. To change a value, double-
click a cell and then enter a value.
The value range depends on the data type. For details, refer to Chapter 2 “1.1 Available
Data” on page 2-1.
Click to toggle display of
HEX
and
BIN
format. To display
HEX
and
BIN
values, click
to display a popup menu, then click
HEX and BIN
and select the check box.
String(European)
,
String(Japanese)
,
String(Chinese)
,
String(Taiwanese)
,
String(Korean)
,
String(Central European)
,
String(Baltic)
,
String(Cyrillic)
:
Displays the current value of device address in string. To change a value, double-click a cell
and then enter the messages in the language selected.
Содержание MICRO/I HG4G-CJT22 F-B Series
Страница 1: ...B 1701 11 User s Manual ...
Страница 26: ...Preface 25 WindO I NV4 User s Manual ...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic Font ANSI 1257 Cyrillic Font ANSI 1251 ...
Страница 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Страница 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Страница 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Страница 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Страница 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Страница 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Страница 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Страница 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Страница 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Страница 1286: ...4 Clear 24 26 WindO I NV4 User s Manual 4 Click Yes 5 Click Close This concludes clearing data ...
Страница 1288: ...4 Clear 24 28 WindO I NV4 User s Manual 6 Click Yes 7 Click Close This concludes clearing data on the external memory device ...
Страница 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Страница 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Страница 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Страница 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Страница 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Страница 1664: ...Index 12 WindO I NV4 User s Manual ...