3 Security Dialog Box
23-44
WindO/I-NV4 User’s Manual
●
Options
Tab
■
Use Password to open a Project
Select this check box and enter a password to protect the project with a dedicated password when opening it.
The number for the password is 4 to 15 characters. Only uppercase alphabetic characters and numbers can be used.
The operations subject to password protection are as follows.
• Opening projects
• Reusing screens
• Opening projects after uploading project data
■
Change User by Device Address
Select this check box to switch the user account according to the value of device address.
The user account is specified by using the number on the
General
tab.
Example: When the trigger device address is D0 and the default user is selected as User1
The user account switches according to the value of device address.
Confirm Password:
Re-enter the password that was entered in
Use Password to open Project
.
Write down the password so you do not forget it and save that note in a safe place.
(Trigger Device Address): Specifies the word device to write the number.
Click
to display the Tag Editor. For the device address configuration procedure, refer to
Chapter 2 “5.1 Device Address Settings” on page 2-68.
1
2
3
No.
User Name
User3
User2
User1
(Default user)
0
User account
Trigger device address
D0 value
Switch to default
user account
1
Switch to user
account no. 1
2
Switch to user
account no. 2
3
Switch to user
account no. 3
4
None
Action
User3
User3
User2
User1
User1
The user account is not switched when the value of
device address is a number not configured to a user
account or an invalid number.
If the value of device address is
0, the user is switched to the
default user.
Содержание MICRO/I HG4G-CJT22 F-B Series
Страница 1: ...B 1701 11 User s Manual ...
Страница 26: ...Preface 25 WindO I NV4 User s Manual ...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic Font ANSI 1257 Cyrillic Font ANSI 1251 ...
Страница 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Страница 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Страница 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Страница 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Страница 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Страница 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Страница 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Страница 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Страница 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Страница 1286: ...4 Clear 24 26 WindO I NV4 User s Manual 4 Click Yes 5 Click Close This concludes clearing data ...
Страница 1288: ...4 Clear 24 28 WindO I NV4 User s Manual 6 Click Yes 7 Click Close This concludes clearing data on the external memory device ...
Страница 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Страница 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Страница 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Страница 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Страница 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Страница 1664: ...Index 12 WindO I NV4 User s Manual ...