
WindO/I-NV4 User’s Manual
3-51
5 User Communication
3
Communic
ation
Device Address
The value of device address is either not converted or converted to ASCII and then sent as data with the specified size.
This can be configured only when
TXD
or
Inching
is selected as
Type
on the Command Settings dialog box, and
Device Address
is selected under
Type
on the Data Settings dialog box.
■
Conversion Type:
Select the conversion rule for the value of device address from the following.
■
Device Address
Specify the source word device for transmitted data. You can only specify an internal device.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-68.
■
Use Reference Device Address
To change the source word device for transmitted data according to values of device address, select this check box
and specify a device address. You can only specify an internal device.
For details, refer to Chapter 2 “Indirect Read and Indirect Write Settings” on page 2-5.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-68.
■
Storage Method of data
Select the handling method for the value of read device address. This can be configured only when
No conversion
is
selected under
Conversion Type
.
■
Number of bytes
Specify the number of bytes of transmitted data. The number of bytes that can be specified varies based on the
setting under
Conversion Type
.
Hexadecimal to ASCII: Considers the value of device address as binary-coded hexadecimal number and converts it
to ASCII data.
Decimal to ASCII:
Considers the value of device address as binary-coded decimal number and converts it to
ASCII data.
No conversion:
No conversion is performed.
from Upper byte: Value of device addresses are read from the upper byte.
from Lower byte: Value of device addresses are read from the lower byte.
Hexadecimal to ASCII: 1 to 4
Decimal to ASCII:
1 to 5
No conversion:
1 to 2
Содержание MICRO/I HG4G-CJT22 F-B Series
Страница 1: ...B 1701 11 User s Manual ...
Страница 26: ...Preface 25 WindO I NV4 User s Manual ...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic Font ANSI 1257 Cyrillic Font ANSI 1251 ...
Страница 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Страница 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Страница 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Страница 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Страница 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Страница 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Страница 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Страница 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Страница 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Страница 1286: ...4 Clear 24 26 WindO I NV4 User s Manual 4 Click Yes 5 Click Close This concludes clearing data ...
Страница 1288: ...4 Clear 24 28 WindO I NV4 User s Manual 6 Click Yes 7 Click Close This concludes clearing data on the external memory device ...
Страница 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Страница 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Страница 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Страница 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Страница 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Страница 1664: ...Index 12 WindO I NV4 User s Manual ...