6 Important Notes
20-58
WindO/I-NV4 User’s Manual
This section describes important notes when defining a script.
6.1 Important Notes Regarding the While Definition
■
Define so it will not go into an infinite loop.
The execution expression is repeatedly executed while the conditional expression is satisfied.
However, it will go into an infinite loop when the conditional expression is satisfied continually.
In the conditional expression of the while definition, it states to exit the loop when the value of LDR100 turns 0. However, the
value stored in the LDR100 is not changed after storing 10 in the first line of the script, so it will go into an infinite loop.
When using the while definition, define it so it will not go into an infinite loop.
The value of LDR100 will become 0 when the while definition is repeated 10 times in the next example, and it will get
out of the while definition.
■
Define it so it will not continue the process for longer than the time limit.
When the processing of a single script continues for more than the time limit due to a while definition, etc., an
execution time over error occurs and that script will be halted. Define the script so the execution time for one script
does not exceed 3,000 milliseconds.
For details, refer to “1.4 Script Error” on page 20-4.
■
Do not write into the external device address.
When it is written into an external device address in the while definition, a script error will occur.
6.2 Number of Device Addresses That Can Be Used
The number of external device addresses that can be used in the script are as follows:
6
Important Notes
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
[LDR 100] = 10;
while (0 != [LDR 100])
{
[LDR 200] = [LDR 200] + 1;
}
[LDR 100] = 10;
while (0 != [LDR 100])
{
[LDR 200] = [LDR 200] + 1;
[LDR 100] = [LDR 100] - 1;
}
Item
Number of devices
Destination external device addresses
64 max.
Source external device addresses
64 max.
• The maximum number of source external device addresses which can be used as a trigger condition and
in scripts executed as Grobal Script is 256.
• When the total number of write data to an external device address exceeds 64 in a single script while
executing a script with MICRO/I, that script will be halted with an error.
Содержание MICRO/I HG4G-CJT22 F-B Series
Страница 1: ...B 1701 11 User s Manual ...
Страница 26: ...Preface 25 WindO I NV4 User s Manual ...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic Font ANSI 1257 Cyrillic Font ANSI 1251 ...
Страница 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Страница 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Страница 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Страница 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Страница 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Страница 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Страница 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Страница 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Страница 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Страница 1286: ...4 Clear 24 26 WindO I NV4 User s Manual 4 Click Yes 5 Click Close This concludes clearing data ...
Страница 1288: ...4 Clear 24 28 WindO I NV4 User s Manual 6 Click Yes 7 Click Close This concludes clearing data on the external memory device ...
Страница 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Страница 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Страница 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Страница 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Страница 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Страница 1664: ...Index 12 WindO I NV4 User s Manual ...