3 Project Settings Dialog Box
4-54
WindO/I-NV4 User’s Manual
3.6 User Communication Tab
The
User Communication
tab is used to configure communication with external devices such as barcode readers.
For details, refer to Chapter 3 “5 User Communication” on page 3-8. This option can only be configured when
User
Communication 1
,
User Communication 2
, or
User Communication 3
is selected for Function under
Interface Settings
on the
Communication Interface
tab.
■
(Protocol List)
Displays the registered user communication protocol.
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
(Protocol List)
(Type)
No.:
Displays the number for managing the user communication protocol.
Protocol Name: Enter the name of the user communication protocol. The maximum number for protocol name is 40
characters.
You cannot use the following characters in the protocol name.
\ /
: , ; * ? " < > |
Receiving Character Time Out (x100 msec)
Specify the time out value (0 to 255) from when 1 frame of data has been received to when the next frame of
data starts to be received. A frame refers to a data string from the beginning to the end of a command. If the
Receiving Character Time Out is set to 0, it is not monitored. These setting items are used only with receive
command.
Example: The received data (1 frame) is 2 bytes, the
While ON
is selected as the
Trigger Type
in the
Trigger
Condition
and LM100 is set to the
Device Address
, LM101 is set to the
Completed Device
Address
, and LDR110 is set to the
Status Device Address
The data of second byte starts to be received before exceeding the Receiving Character Time Out
duration after the data of first byte is received, and the values of the Completed Device Address and
Status Device Address when receiving of the data has been successfully completed are as follows.
• The value of the Completed Device Address LM101 changes to 1.
When the
Not Clear Completed Device Address automatically
check box is not selected, when
the value of the Trigger Condition device address LM100 changes from 0 to 1, the value of the
Completed Device Address LM101 changes to 0.
When the
Not Clear Completed Device Address automatically
check box is selected, the value
of Completed Device Address LM101 remains 1, so set 0 if necessary.
:
Содержание MICRO/I HG4G-CJT22 F-B Series
Страница 1: ...B 1701 11 User s Manual ...
Страница 26: ...Preface 25 WindO I NV4 User s Manual ...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic Font ANSI 1257 Cyrillic Font ANSI 1251 ...
Страница 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Страница 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Страница 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Страница 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Страница 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Страница 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Страница 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Страница 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Страница 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Страница 1286: ...4 Clear 24 26 WindO I NV4 User s Manual 4 Click Yes 5 Click Close This concludes clearing data ...
Страница 1288: ...4 Clear 24 28 WindO I NV4 User s Manual 6 Click Yes 7 Click Close This concludes clearing data on the external memory device ...
Страница 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Страница 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Страница 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Страница 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Страница 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Страница 1664: ...Index 12 WindO I NV4 User s Manual ...