Preparation
Prepare the installation area:
1.
Using the
brick box
as a template, make a hole in the wall where the
intercom
will be located.
2.
Place the
brick box
in the cavity where the
intercom
will be located and mark the 4 screw holes.
3.
Drill 4 screw anchor holes as marked. A drill hole depth of 50mm is recommended.
4.
Insert the screw anchors into the holes.
Brick Box Mounting
Secure the brick box into the wall cavity:
1.
Pull the cable through the cable hole in the
brick box
, leaving 15-20cm excess cable length.
2.
Using the 4 TA5 40mm screws, mount the
brick box
inside the wall cavity.
Note
: the brick box should be as close to flush with the wall as possible
-
Up to 6mm inside the wall cavity is acceptable, but it must not extend beyond the wall surface
-
Angle slope should be within 2°
3.
Fill the gaps between the brick box and the wall with cement.
Note
: this step can be skipped. However it will decrease the anti-punch strength
Do not proceed until the cement has set.
PRT-IPIC-POE-C | Vandal Resistant VoIP Intercom with Camera | Installation Manual