M-7084 User Manual, Rev. A1.3 7PH-013-A13
54
Examples:
Command: $0153A
Response: !01
Sets channels 1, 3, 4, and 5 to count and all other
channels not counting for module 01. The module
returns a valid response.
Command: $016
Response: !013A
Reads the counting status of module 01 and returns a
response of 3A, meaning that channels 1, 3, 4, and 5 are
counting and all other channels are not counting.
Related Commands:
Section 2.13 $AA6
Note:
The command is not available to the channels that are set to
type code 51, frequency measurement.