The main menu is made up of a group of graphic icons (shortcuts) that 
allow rapid access to measurements and settings. 

 

Starting from normal viewing, press 

 

key. The main menu screen is 

displayed. 

 

Press ▲or ▼ to rotate clockwise/counter clockwise to select the 
required function. The selected icon is highlighted and the central part of 
the display shows the description of the function. 

 

 Press 

 to activate the selected function. 

 

If some functions are not available, the correspondent icon will be 
disabled, that is shown in a light grey colour. 

 

 

 

 

 etc.  - Shortcuts that allow jumping to the first page of that 

group. Starting from that page it is still possible to move forward-
backward in the usual way. 

 

 

 - Switch the operation to manual or automatic mode. 

 

 –Opens the password entry page, where it is possible to specify the 

numeric codes that unlock protected functions (parameter setting, 
commands menu). 

 

 – Access point to the setup menu for parameter programming. See 

dedicated chapter. 

 

 – Access point to the commands menu, where the authorised user 

can execute some clearing-restoring actions. 

   

Главное меню

 

 

Главное меню представлено рядом графических значков (ярлыков), 
обеспечивающих легких доступ к показаниям и настройкам. 

 

В режиме обычного просмотра нажмите кнопку 

. Откроется экран главного 

меню. 

 

Нажмите кнопку ▲ или ▼ для перехода по часовой стрелке или против 
часовой стрелки и выбора нужной функции. Выбранный значок будет 

выделен, и описание функции будет показано в центральной области экрана. 

 

 Нажмите 

, чтобы активировать выбранную функцию. 

 

Если какие-либо функции недоступны, соответствующий значок будет 
неактивен и представлен светло-серым цветом. 

 

 

 

 

 и т.д. – значки для перехода на первую страницу группы. С 

этой страницы можно по-прежнему переходить вперед и назад, как обычно. 

 

 

 – переключение в ручной или автоматический режим. 

 

 – открытие страницы ввода пароля для указания числового кода, 

позволяющего получить доступ к защищенным функциям (установка 
параметров, меню команд). 

 

 – доступ к меню настройки для программирования параметров. См. 

отдельную главу. 

 

 – доступ к меню команд, с помощью которого пользователь с 

соответствующими правами может выполнять ряд действий по удалению и 

восстановлению данных. 

 

   

 
 
 

 

 
 
 

 

   

 
 
 

 

    

 

Password access 

 

The password is used to enable or lock the access to setting menu 
(setup) and to commands menu. 

 

For brand-new devices (factory default), the password management is 
disabled and the access is free. If instead the passwords have been 
enabled and defined, then to get access, it is necessary to enter the 
password first, specifying the numeric code through the keypad. 

 

To enable password management and to define numeric codes, see 
setup menu 

M15 Password

 

There are two access levels, depending on the code entered: 

 

User-Level access

 – Allows clearing of recorded values and the 

editing of a restricted number of setup parameters. 

 

Advanced access level – 

Same rights of the user access plus full 

settings editing-restoring. 

 

From normal viewing, press 

 

to recall main menu, select the password 

icon and press 

.

 

 

The display shows the screen in picture: 

   

Парольный доступ

 

 

С помощью пароля можно ограничивать или разрешать доступ к меню 
настроек (установок) и меню команд. 

 

На новых устройствах (с заводскими настройками) пароль отключен и доступ 
не ограничен. При включении и установке парольной защиты пользователь 

может получить доступ только после ввода пароля в виде числового кода с 
помощью кнопок. 

 

Для включения функции управления паролями перейдите в меню настройки 

M15 Пароль

 

В зависимости от введенного кода предусмотрено два уровня доступа: 

 

Пользовательский доступ

 – удаление значений из памяти и 

изменение ограниченного числа параметров настройки. 

 

Расширенный доступ – 

полномочия пользовательского доступа плюс 

полный доступ на редактирование и восстановление настроек. 

 

В режиме обычного просмотра нажмите 

, чтобы вызвать главное меню, 

выберите значок пароля и нажмите 

.

 

 

На экране будет показано следующее: 

 

 

   

 

 

 

Keys ▲and ▼change the selected digit 

 

Keys 

◄ 

and

 ► 

move through the digits. 

 

Enter all the digits of the numeric code, then move on the 

key

 icon.  

 

If the password code entered matches the 

User access code

 or the 

Advanced access code

, then the correspondent unlock message is 

shown. 

 

Once unlocked the password, the access rights last until: 

o

 

the device is powered off. 

o

 

the device is reset (after quitting the setup menu). 

o

 

the timeout period of two minutes elapses without any keystroke.  

 

To quit the password entry screen press 

key. 

   

 

С помощью кнопок ▲ и ▼ изменяйте выбранную цифру 

 

С помощью кнопок 

◄ 

и

 ► 

перемещайтесь по цифрам. 

 

Введите все цифры числового кода, после чего перейдите на значок 

ключа

.  

 

Если введенный код пароля совпадает с 

Кодом пользовательского доступа

 

или 

Кодом расширенного доступа

, будет показано сообщение с 

подтверждением разблокирования. 

 

После разблокирования права доступа сохраняются: 

o

 

до отключения питания устройства. 

o

 

до момента сброса устройства (после выхода из меню настройки). 

o

 

по истечении двух минут при условии отсутствия нажатий на кнопки.  

 

Чтобы закрыть экран ввода пароля, нажмите кнопку 

.

 

Переход в 

автоматический 

режим 

Страница 

напряжения/тока 

 

Журнал 

регистрации 

событий 

 

Страница 
мощности 

Статистика  

Продолжитель-

ности ступени 

Гармоники 

 

Страница 

информации о 

системе 

Меню настройки 

Меню команд  

 

Ввод пароля 

Главная страница  

Переход в ручной 

режим 

Switches to 

Automatic mode 

Voltage – current 

page 

 

Event Log 

 

Power page 

Step life  

statistics 

Harmonics 

 

System information 

page 

Setup Menu 

Commands   

menu  

 

Password entry 

Main page  

Switches to Manual 

mode 

ЧП

 «

Профиэлектро

» 

Т

. +380 44 361-62-55, 80 

e-mail: [email protected] 

www. profielectro.net.ua 

Содержание RPC 8BGA

Страница 1: ...Main menu 4 Password access 4 Display page navigation 5 Table of display pages 5 Harmonic analysis page 7 Waveform pages 7 Expandability 8 Additional resources 9 Communication channels 9 Inputs output...

Страница 2: ...y outputs o Additional analog I O for PT100 temperature current voltage Capability to operate with several units interconnected in Master Slave mode o Maximum configuration Master 8 slave o Max 32 ste...

Страница 3: ...t the step is not available because its reconnection time is not yet exhausted In this case sending a command to close the step number will flash to indicate that the operation has been confirmed and...

Страница 4: ...d and the access is free If instead the passwords have been enabled and defined then to get access it is necessary to enter the password first specifying the numeric code through the keypad To enable...

Страница 5: ...o the display remains were it was last You can set this function in menu M01 Utility M01 Utility Table of display pages PAGES EXAMPLE Home page Power Voltage and current Step life statistics Temperatu...

Страница 6: ...function is disabled For example if the limit function is not programmed the corresponding page won t be shown Event time stamp Event description Event number total Key switches between Total Partial...

Страница 7: ...eric format selecting the required order through and The lower part of the screen will display a little arrow that points to the selected column and the relative percentage value of the three phases T...

Страница 8: ...figuration will be saved and will become effective otherwise the mismatch will be shown at every subsequent power on of the system The present system configuration is shown in the dedicated page of th...

Страница 9: ...hernet RS485 DCRG RS 485 Ethernet DCRG Ethernet COM1 COM2 COM3 Gateway DCRG Gateway Inputs outputs internal variables counters analog inputs The inputs and outputs are identified by a code and a seque...

Страница 10: ...is less than the Lower threshold for the programmed delay When the measured value becomes higher than the upper setpoint after the set delay the LIM status is reset Max function the upper threshold de...

Страница 11: ...protections like panel or capacitor overtemperature no voltage release harmonic protections etc The maximum possible configuration is one master with 8 slaves Example 1 application in series It is req...

Страница 12: ...gical step and pairing step between logical and physical outputs of the master and the slave The program is then automatically extended to the slaves On the slave it is only necessary to set the slave...

Страница 13: ...8 guaranteeing the greatest safety for the operator o High speed data transfer o IP54 front panel o Limits the possibility of unauthorized access with device config Simply hold the CX dongle up to the...

Страница 14: ...e panel M18 HARMONIC PROT Harmonic protections EXP1016 module M19 MISCELLANEOUS Various settings M20 LIMIT THRESHOLDS Limit thresholds on measurements M21 COUNTERS Generic programmable counters M22 AN...

Страница 15: ...to go back to the parameter selection The entered value is stored Press to save all the settings and to quit the setup menu The controller executes a reset and returns to normal operation If the user...

Страница 16: ...estore delay when no key pressed If set to OFF the display will always show the last page selected manually P01 08 Default page displayed on power up and after delay P01 09 Free text with alphanumeric...

Страница 17: ...number of the step on the main page is shown in light gray P02 11 Connection sensitivity This parameter sets the speed of reaction of the controller With small values of P02 11 regulation is fast more...

Страница 18: ...ws to avoid regulation oscillations Set this value according to the technical characteristics closing time declared by the manufacturer of the static contactor P02 30 Enables the setting of the setpoi...

Страница 19: ...the previous parameter Example If the output function is set to Alarm Axx and you want this output to be energized for alarm A31 then P04 n 02 should be set to value 31 P04 n 3 Sets the state of the...

Страница 20: ...4 PROGRAMMABLE INPUTS INPn n 1 8 UdM Default Range P14 n 01 INPn input function various see Input functions table P14 n 02 Function index x OFF OFF 1 99 P14 n 03 Contact type NO NO NC P14 n 04 Delay O...

Страница 21: ...U Modbus ASCII Modbus TCP P16 n 06 IP address 192 168 1 1 000 000 000 000 255 255 255 255 P16 n 07 Subnet mask 255 255 255 0 000 000 000 000 255 255 255 255 P16 n 08 IP port 1001 0 9999 Note this menu...

Страница 22: ...milar P17 08 Trip threshold for the capacitors overload protection alarm A08 that will arise after a integral delay time inversely proportional to the value of the overload P17 09 Threshold beyond whi...

Страница 23: ...100 P18 n 08 5 1 100 P18 n 09 7 1 100 P18 n 10 11 1 100 P18 n 11 13 1 100 P18 n 12 1 55 0 212 P18 n 13 2 55 0 212 EXP1016 P18 n 01 P18 n 02 P18 n 03 2 1 P18 n 04 P18 n 05 P18 n 06 A11 P18 n 07 A12 P18...

Страница 24: ...ould be connected to the appropriate terminal for the type selected See input module manual P22 n 02 and P22 n 03 Define the value to display for a min sensor signal in other words at the start of the...

Страница 25: ...Active energy Kvarh Reactive energy kVA Apparent energy P24 n 02 The quantity of energy which must accumulate for a pulse to be emitted for example 10Wh 100Wh 1kWh etc P24 n 03 Pulse duration Applicat...

Страница 26: ...function P26 n 10 Modem call A modem is connected as configured in setup P26 n 11 No LCD The alarm is managed normally but not shown on the display P26 n 12 13 Delay time Time delay in minutes or sec...

Страница 27: ...eshold set with P18 n 11 A17 Harmonic protection Module nr n Temperature 1 too high The temperature 1 measured by the harmonic protection module is higher than threshold set with P18 n 12 A18 Harmonic...

Страница 28: ...LOC 10 A19 LEN GEN 0 UAx GEN 0 Input function table The following table shows all the functions that can be attributed to the INPn programmable digital inputs Each input can be set for an reverse fun...

Страница 29: ...Energised when global alarm 2 is active Global alarm 3 Energised when global alarm 3 is active Fan Panel ventilation fan Manual mode Active when the regulator is in MAN mode Automatic mode Active when...

Страница 30: ...Senphi L3 26 W TOT Total active power 27 var TOT Total reactive power 28 VA TOT Total apparent power 29 Cosphi TOT Cosphi balanced three phase system 30 Senphi TOT Senphi balanced three phase system...

Страница 31: ...he backup of user settings Once the required command has been selected press to execute it The device will prompt for a confirmation Pressing again the command will be executed To cancel the command e...

Страница 32: ...arameter setting P02 03 Three phase P02 04 L3 P02 06 L1 L2 P02 22 LV P02 03 P02 04 L3 P02 06 L1 L2 P02 22 Single phase wiring SINGLE PHASE CONNECTION Voltage measure 1 phase voltage reading L1 N 1 L1...

Страница 33: ...2 22 FULL THREE PHASE CONNECTION WITH NEUTRAL Wiring configuration used for standard applications with full three phase voltage control Voltage measure 3 ph to n and 3 ph to ph voltage readings L1 N L...

Страница 34: ...V P02 23 ON P02 03 P02 04 L3 P02 06 L1 L2 P02 22 P02 23 Configuration with MV measurement and correction Voltage measure 3 ph to ph voltage reading L1 L2 L2 L3 L3 L1 on MV side 3 L1 L2 L2 L3 L3 L1 Cur...

Страница 35: ...0 90 Capacitor overload current measure 3 Readings on L1 L2 L2 L3 L3 L1 3 L1 L2 L2 L3 L3 L1 Parameter setting P02 03 Three phase P02 04 L1 L2 L3 P02 06 L1 L2 L3 P02 22 LV P02 29 Fast P02 03 P02 04 L1...

Страница 36: ...01 Stepx P07 1 01 Stepx P08 1 02 Stepx P05 01 COM1 P05 02 Slave01 P05 01 COM1 P05 02 Slave02 P05 01 COM1 P05 02 Slave03 P05 01 COM1 P05 02 P05 03 P05 04 P05 05 P04 1 01 x P06 1 01 x P07 1 01 x P08 1 0...

Страница 37: ...morsetti OUT 1 600V 50 60 Hz OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 SLOT 1 SLOT 2 SLOT 3 SLOT 4 Dimensioni meccaniche e foratura pannello mm 380 44 361 62 55 80 e mail info profielectro net ua www...

Страница 38: ...age 415V 415 Rated current AC1 5A 250V AC15 1 5A 415V AC1 5A 250 AC15 1 5A 415 Real time clock Energy storage Back up capacitors Operating time without supply voltage About 12 15 days 12 15 Insulation...

Страница 39: ...phase neutral voltage 300V 300 Rev Date Notes 00 30 10 2012 First release 00 30 10 2012 01 28 01 2013 Added Tanfi parameters P02 30 e P02 31 01 28 01 2013 tanfi P02 30 P02 31 380 44 361 62 55 80 e ma...

Отзывы: