4.
Make
sure
that
the
heat-sink
retaining
clip
is
open.
5.
If
you
are
installing
a
new
heat
sink,
remove
the
cover
from
the
bottom
of
the
heat
sink.
If
you
are
reinstalling
a
heat
sink
that
was
previously
removed,
see
for
instructions
for
replacing
the
contaminated
or
missing
thermal
grease;
then,
return
to
this
step.
6.
If
necessary,
remove
the
cover
from
the
bottom
of
the
heat
sink.
7.
Position
the
heat
sink
above
the
microprocessor,
making
sure
that
the
word
“Front”
is
closest
to
the
front
of
the
server;
then,
press
the
heat
sink
into
place
and
close
the
heat-sink
release
lever.
FR
ONT
Heat sink
Heat sink
retention clip
Note:
If
you
are
installing
an
additional
microprocessor
in
microprocessor
socket
3
or
4,
you
must
also
install
a
VRM.
8.
If
necessary,
install
a
VRM
in
the
connector.
a.
Open
the
retaining
clips
on
each
end
of
the
VRM
connector.
b.
Turn
the
VRM
so
the
keys
align
with
the
slot.
c.
Insert
the
VRM
into
the
connector
by
aligning
the
edges
of
the
VRM
with
the
slots
at
the
end
of
the
VRM
connector.
Firmly
press
the
VRM
straight
down
into
the
connector
by
applying
pressure
on
both
ends
of
the
VRM
simultaneously.
The
retaining
clips
snap
into
the
locked
position
when
the
VRM
is
seated
in
the
connector.
9.
Install
the
air
baffle
in
the
microprocessor
tray.
Note:
Make
sure
that
the
air
baffle
lies
flat
and
within
the
grooves
on
top
of
the
microprocessor
heat
sinks
and
microprocessor
baffles
and
that
the
air
baffle
remains
in
place
while
you
close
the
microprocessor
tray.
You
might
find
it
helpful
to
hold
the
air
baffle
in
place
with
your
thumbs
while
closing
the
microprocessor
tray.
10.
Install
the
microprocessor
tray
in
the
server:
a.
Make
sure
that
the
microprocessor-tray
release
latch
is
open;
then,
push
the
microprocessor
tray
into
the
server.
b.
Close
the
tray
levers
and
make
sure
they
are
securely
latched.
c.
Close
the
microprocessor-tray
release
latch.
d.
Reinstall
the
fans
and
memory
cards
in
the
server.
11.
Install
the
bezel
and
front
cover
(tower
model
only)
(see
12.
Connect
the
cables
and
power
cords
(see
for
cabling
instructions).
13.
Turn
on
all
attached
devices
and
the
server.
Chapter
4.
Removing
and
replacing
server
components
149
Содержание x3800 - System - 8865
Страница 1: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 122: ...106 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 130: ...114 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 182: ...166 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 195: ......
Страница 196: ...Part Number 31R1860 Printed in USA 1P P N 31R1860...