Error
code
Description
Action
217-xxx-007
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Reseat
hard
disk
drive
8.
2.
Replace
hard
disk
drive
8.
217-xxx-008
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Reseat
hard
disk
drive
9.
2.
Replace
hard
disk
drive
9.
217-xxx-009
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Reseat
hard
disk
drive
10.
2.
Replace
hard
disk
drive
10.
217-xxx-010
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Reseat
hard
disk
drive
11.
2.
Replace
hard
disk
drive
11.
217-xxx-011
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Reseat
hard
disk
drive
12.
2.
Replace
hard
disk
drive
12.
217-198-xxx
Could
not
establish
drive
parameters.
1.
Check
the
drive
cables
and
terminators.
2.
Reseat
the
hard
disk
drive.
3.
Replace
the
hard
disk
drive.
301-xxx-000
Failed
keyboard
test.
Note:
After
installing
a
USB
keyboard,
you
might
have
to
use
the
Configuration/Setup
Utility
program
to
enable
keyboardless
operation
and
prevent
the
POST
error
message
301
from
being
displayed
during
startup.
1.
Reseat
the
following
components:
a.
Keyboard
b.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
302-xxx-xxx
Failed
mouse
test.
1.
Reseat
the
following
components:
a.
Mouse
b.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
305-xxx-xxx
Failed
video
monitor
test.
1.
Reseat
the
following
components:
a.
Monitor
b.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
405-xxx-000
Failed
Ethernet
test
on
controller
on
I/O
board.
1.
Make
sure
that
Ethernet
is
not
disabled
in
the
Configuration/Setup
Utility
program
and
that
the
BIOS
code
is
at
the
latest
level.
2.
Run
the
loopback
diagnostic.
3.
Reseat
the
I/O
board.
4.
Replace
the
I/O
board.
88
IBM
System
x3800
Type
8865:
Problem
Determination
and
Service
Guide
Содержание x3800 - System - 8865
Страница 1: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 122: ...106 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 130: ...114 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 182: ...166 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 195: ......