v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
166-400-100
DMC
Self
Test
Result
failed
tests:
xxx
where
xxx=flash,
ROM,
or
RAM.
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
2.
Update
the
BIOS
code,
BMC,
service
processor,
and
diagnostics
firmware
(see
180-197-000
SCSI
ASPI
driver
not
installed.
1.
Remove
the
RAID
adapter,
if
one
is
installed,
and
run
the
test
again.
2.
Reseat
the
following
components:
a.
SAS
hard
disk
drive
backplane
cables
b.
I/O
board
c.
Microprocessor
tray
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
SAS
hard
disk
drive
backplane
b.
I/O
board
c.
(Trained
service
technician
only)
Microprocessor
tray
180-361-003
Failed
fan
LED
test.
1.
Reseat
the
following
components:
a.
Fan
b.
I/O
board
2.
Replace
the
components
listed
above
one
at
a
time,
in
the
order
listed
above,
restarting
the
server
each
time.
180-xxx-000
Diagnostics
LED
failure.
Run
the
diagnostic
LED
test
for
the
failing
LED.
180-xxx-001
Failed
front
LED
panel
test.
1.
Reseat
the
following
components:
a.
Operator
information
panel
b.
I/O
board
c.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Operator
information
panel
b.
I/O
board
c.
(Trained
service
technician
only)
Microprocessor
tray
84
IBM
System
x3800
Type
8865:
Problem
Determination
and
Service
Guide
Содержание x3800 - System - 8865
Страница 1: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 122: ...106 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 130: ...114 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 182: ...166 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 195: ......
Страница 196: ...Part Number 31R1860 Printed in USA 1P P N 31R1860...