000
The
server
passed
the
test.
Do
not
replace
a
CRU
or
FRU.
195
The
Esc
key
was
pressed
to
end
the
test.
Do
not
replace
a
CRU
or
FRU.
197
This
is
a
warning
error,
but
it
does
not
indicate
a
hardware
failure;
do
not
replace
a
CRU
or
FRU.
Take
the
action
that
is
indicated
in
the
Action
column
but
do
not
replace
a
CRU
or
a
FRU
.
See
the
description
of
Warning
in
for
more
information.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
001-198-000
Test
aborted.
1.
Check
the
system-error
log
and
the
BMC
log
for
messages
that
indicate
the
cause
of
the
error,
and
take
the
indicated
action.
2.
From
the
diagnostic
programs,
run
Quick
Memory
Test
All
Banks;
then,
if
an
error
is
detected,
take
the
indicated
action.
3.
Reinstall
and,
if
necessary,
update
the
BIOS
code
on
the
server;
then,
rerun
the
test
(see
001-250-00x
Test
failed,
where
v
x
of
0
=
ECC
logic
on
I/O
board
v
x
of
1
=
ECC
logic
on
memory
card
1.
Check
the
system-error
log
and
the
BMC
log
for
messages
that
indicate
the
cause
of
the
error,
and
take
the
indicated
action.
2.
From
the
diagnostic
programs,
run
Quick
Memory
Test
All
Banks;
then,
if
an
error
is
detected,
take
the
indicated
action.
3.
From
the
diagnostic
programs,
run
the
ECC
test
again;
then,
if
an
error
is
detected,
take
the
indicated
action.
4.
Reseat
the
following
components:
a.
Memory
card
b.
I/O
board
5.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
001-292-000
Core
system:
failed/CMOS
checksum
failed.
Load
the
BIOS
default
settings
by
using
the
Configuration/Setup
Utility
program
and
run
the
test
again
(see
001-xxx-000
Failed
core
tests.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
001-xxx-001
Failed
core
tests.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
005-xxx-000
Failed
video
test.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
011-xxx-000
Failed
COM1
serial
port
test.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
Chapter
2.
Diagnostics
73
Содержание x3800 - System - 8865
Страница 1: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 122: ...106 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 130: ...114 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 182: ...166 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 195: ......
Страница 196: ...Part Number 31R1860 Printed in USA 1P P N 31R1860...