![IBM x3800 - System - 8865 Скачать руководство пользователя страница 110](http://html2.mh-extra.com/html/ibm/x3800-system-8865/x3800-system-8865_manual_3342325110.webp)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
System-error
log
message
Action
CPU
%d
non-critical
over
temperature
warning
1.
Make
sure
that
the
fans
have
good
airflow
and
are
not
obstructed.
2.
(Trained
service
technician
only)
Reseat
the
microprocessor
heat
sink.
CPU
%d
non-recoverable
over
temperature
fault
1.
Make
sure
that
the
fans
have
good
airflow
and
are
not
obstructed.
2.
(Trained
service
technician
only)
Reseat
the
microprocessor
heat
sink.
CPU
removal
detected
Informational
only;
if
the
message
remains:
1.
(Trained
service
technician
only)
Reseat
the
microprocessors.
2.
Reseat
the
microprocessor
VRMs,
if
any
are
present.
CPU
X
Over
Temperature
1.
Check
all
fans
and
remove
any
obstacles
from
the
path
of
the
airflow.
2.
Make
sure
that
the
room
temperature
is
within
the
recommended
range.
3.
Make
sure
that
the
microprocessor
heat
sinks
are
correctly
seated.
Ethernet
Data
Rate
modified
from
<value1>
to
<value2>
by
user
<USERID>
Information
only
Ethernet
Duplex
setting
modified
from
<value1>
to
<value1>
by
user
<USERID>
Information
only
Ethernet
interface
<value>
by
user
<USERID>
Information
only
Ethernet
locally
administered
MAC
address
modified
from
x:x:x:x:x:x
Information
only
Ethernet
MTU
setting
modified
from
x
to
y
by
user
<USERID>
Information
only
Fan
X
Failure
(X
of
1-8)
1.
Make
sure
that
nothing
is
blocking
the
fan.
2.
Check
the
physical
connection
and
make
sure
that
the
fan
is
correctly
seated.
3.
Replace
fan
X.
Fan
X
not
detected
(X
of
1-8)
1.
Make
sure
that
nothing
is
blocking
the
fan
or
power
supply.
2.
Check
the
physical
connection
and
make
sure
that
the
fan
is
correctly
seated.
3.
Replace
fan
X.
Operator
information
panel
is
not
plugged
in
1.
Make
sure
that
the
operator
information
panel
cables
are
correctly
connected
(verify
LED
activity).
2.
Replace
the
operator
information
panel.
94
IBM
System
x3800
Type
8865:
Problem
Determination
and
Service
Guide
Содержание x3800 - System - 8865
Страница 1: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 28: ...12 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 122: ...106 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 130: ...114 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 182: ...166 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Страница 195: ......
Страница 196: ...Part Number 31R1860 Printed in USA 1P P N 31R1860...