4-12
TS2900 Tape Autoloader Setup, Operator, and Service Guide
To restore your library configuration, see “Saving and Restoring Configuration
Settings” on page 4-28.
Servicing the Library
The Service menu on the Operator Panel gives users access to troubleshooting and
maintenance diagnostic tools.
Checking the Library Error Status
Figure 4-25. Error status menu
Use
Service
→
View Error Status
to check the current status of the major library
components.
Select the component to view its error status:
•
Library
— Checks the error status of the library.
•
Drive
— Checks the error status of the tape drive.
If an error occurs, press the Enter key to display specific error information. You can
check the meaning of error codes in Appendix B, “Error Codes,” on page B-1.
Running Library Verify Diagnostics
Figure 4-26. Library Verify diagnostics
Use
Service
→
Diagnostics
→
Run Library Verify
to test the library and drive
hardware, communications, and the read/write capability of the library. Library
Verify is the most critical and most frequently used test, and should be executed after
all maintenance procedures to ensure correct library performance.
Note:
Running the Library Verify diagnostic test will unload tape cartridges in the
drives if the host application has not already done so.
To run library verification diagnostic tests:
1.
Select
Run Library Verify
, and press Enter. Follow the on-screen instructions.
The library performs a Power ON Self Test (POST), the normal test sequence
performed when the library is turned ON, to ensure that the library hardware is
functional. Then, the library tests communications with the tape drive over the
internal bus. If there is a cartridge in the drive, the library moves the cartridge to
its home position, or to the I/O Station if the home position is not known.
2.
When prompted, insert a scratch cartridge into the I/O Station.
When the scratch cartridge is loaded, an inventory is conducted and the bar code
reader reads the bar code label on the cartridge and stores it for later comparison.
The scratch cartridge is then moved to the tape drive, where the drive runs its
own write/read/verify test. When the test is done, the library tells the drive to
View Drive Error Status
View Library Error Status
Service
View Error Status
Run Library Verify
Service
Diagnostics
Содержание System Storage TS2900
Страница 2: ......
Страница 10: ...viii TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 14: ...xii TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 22: ...xx TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 24: ...xxii TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 36: ...1 12 TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 78: ...3 34 TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 114: ...4 36 TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 136: ...5 22 TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 192: ...A 22 TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 220: ...D 10 TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 230: ...F 4 TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 232: ...G 2 TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 238: ...H 6 TS2900 Tape Autoloader Setup Operator and Service Guide...
Страница 255: ......
Страница 256: ...Part Number 45E3877 Printed in USA GC27 2212 00 1P P N 45E3877...
Страница 257: ...Spine information IBM System Storage TS2900 Tape Autoloader Setup Operator and Service Guide Machine Type 3572...