13.
Remove the four memory modules and place them on a static-protective surface for reinstallation.
See “Removing the memory modules (DIMM)” on page 104.
14.
Remove the heat-sink air baffle and the heat sink. Clean the thermal grease from the microprocessor
before you remove it. You can also clean the heat sink now.
15.
Remove the microprocessor. See “Removing the microprocessor” on page 251.
16.
Notice the orientation of the microprocessor retention module and then remove the four screws (
1
in Figure 280 on page 280) that hold the microprocessor retention module to the system board. Then,
lift the retention module out of the server.
1
2
3
svc00489
Figure 279. Connectors for the SAN Volume Controller 2145-8A4 heat exchange fans