1
Side connector latch
2
Memory clips
3
Memory module
7.
If you have other tasks to complete inside the SAN Volume Controller, do those tasks now.
Replacing the memory modules (DIMM)
The memory modules are electrostatic-discharge (ESD) sensitive. Take precautions to avoid damage from
static electricity.
There are two versions of the SAN Volume Controller 2145-8G4 node: Rev 1 and Rev 2. One difference
between these two versions is in the memory configuration. The original version (Rev 1) has eight 1 GB
memory modules, while the second version (Rev 2) has four 2 GB memory modules. The label on the
Rev 1 node does not include a version number. An additional label on the front of the Rev 2 node
includes the version number. Ensure that you have the correct memory modules for the node that you
are servicing.
Perform the following steps to replace the memory modules:
Attention:
To avoid breaking the retaining clips or damaging the memory module connectors, open and
close the clips gently.
1.
With the clips
2
open, lower the memory module
3
into the connector, as shown in Figure 98 on
page 110. Insert the DIMM fully to close the clips.
1
2
3
1
2
22u9qm
Figure 97. Removing the memory modules
Chapter 2. Removing and replacing parts
109
Содержание SAN Volume Controller 2145-CG8
Страница 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Страница 2: ......
Страница 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Страница 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 371: ......
Страница 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...