![background image](http://html1.mh-extra.com/html/ibm/san-volume-controller-2145-cg8/san-volume-controller-2145-cg8_hardware-maintenance-manual_4016998176.webp)
To remove the CMOS battery, perform the following steps:
1.
Turn off the node while ensuring that its data is mirrored and synchronized. See MAP 5350 in the
IBM System Storage SAN Volume Controller Troubleshooting Guide
for more information.
2.
Remove the cable-retention bracket and disconnect the power cable from the node. See “Removing the
cable-retention bracket” on page 34.
3.
Remove the top cover. See “Removing the top cover” on page 77.
4.
Locate the battery
1
on the system board. Figure 135 shows the location of the battery.
5.
Remove the CMOS battery, as shown in Figure 136:
a.
Use a fingernail to press the top of the battery clip away from the battery. The battery pops up
when released.
b.
Use your thumb and index finger to lift the battery from the socket.
Removing the SAN Volume Controller 2145-8F4 or SAN Volume Controller
2145-8F2 CMOS battery
This topic describes how to remove the SAN Volume Controller 2145-8F4 and SAN Volume Controller
2145-8F2 CMOS battery.
1
svc00301
Figure 135. Location of the SAN Volume Controller 2145-8G4 CMOS battery holder
svc00276
Figure 136. SAN Volume Controller 2145-8G4 CMOS battery holder
146
IBM SAN Volume Controller Hardware Maintenance Guide
Содержание SAN Volume Controller 2145-CG8
Страница 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Страница 2: ......
Страница 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Страница 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 371: ......
Страница 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...