2.
Lift the locking levers (
1
in Figure 37) on the slide rails and push the server
2
all the way into the
rack until it clicks into place.
3.
Replace the cable-management arm. See “Replacing the cable-management arm” on page 30.
4.
Reconnect the Fibre Channel and Ethernet cables. Ensure that you replace the Fibre Channel and
Ethernet cables in the same ports from which they were removed.
5.
Connect the power cable to the node and replace the cable-retention bracket. See “Replacing the
cable-retention bracket” on page 39.
6.
Replace the cable-management arm, as described in “Replacing the cable-management arm” on page
30.
7.
Turn on the node.
Replacing the SAN Volume Controller 2145-8A4 in a rack
Follow these instructions when you are prompted to replace the SAN Volume Controller 2145-8A4.
Attention:
Do not touch the power control switches on adjacent SAN Volume Controller nodes when
you remove or install SAN Volume Controller nodes in a rack. Touching these switches on adjacent SAN
Volume Controller nodes might cause those devices to turn off and make customer data inaccessible.
Perform the following steps to replace the SAN Volume Controller 2145-8A4 node in a rack:
1.
Align the node on the slide rails and push the node fully into the rack. Secure the node to the front
mounting flanges with the captive thumbscrews (
1
svc_bb1ka055
Figure 37. Raising the 2145-CG8 or 2145-CF8 locking levers of the slide rails of the rack
58
IBM SAN Volume Controller Hardware Maintenance Guide
Содержание SAN Volume Controller 2145-CG8
Страница 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Страница 2: ......
Страница 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Страница 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 371: ......
Страница 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...