Chapter 1. General description
5
1.2 Operating environment
Table 1-1 lists the operating environment specifications for the servers.
Table 1-1 Operating environment for Power 720 and Power 740
Power 720 and Power 740 operating environment
Description
Operating
Non-operating
Power 720
Power 740
Power 720
Power 740
Temperature
5 - 35 degrees C (41 - 95 degrees F)
Recommended: 18 - 27 degrees C
(64 - 80 degrees F)
5 - 45 degrees C (41 to 113 degrees F)
Relative
humidity
8 - 80%
8 - 80%
Maximum dew
point
28 degrees C (84 degrees F)
28 degrees C (84 degrees F)
Operating
voltage
100 - 127 VAC or
200 - 240 VAC
200 - 240 V AC
N/A
Operating
frequency
47 - 63 Hz
N/A
Power
consumption
995 Watts
maximum
1630 Watts
maximum
N/A
Power source
loading
1.015 kVa
maximum
1.664 kVa
maximum
N/A
Thermal output
3395 Btu/hour
maximum
5562 Btu/hour
maximum
N/A
Maximum
altitude
3050 m
(10,000 ft)
N/A
Noise level
reference point
:
Tower system:
5.6 bels
(operating)
5.5 bels (idle)
Rack system:
5.6 bels
(operating)
5.5 bels (idle)
Rack system:
6.0 bels
(operating)
5.9 bels (idle)
N/A
Note: The maximum measured value is expected from a fully populated server under an
intensive workload. The maximum measured value also accounts for component tolerance
and operating conditions that are not ideal. Power consumption and heat load vary greatly
by server configuration and utilization. Use the IBM Systems Energy Estimator to obtain a
heat output estimate based on a specific configuration:
http://www-912.ibm.com/see/EnergyEstimator