100
IBM Power 720 and 740 Technical Overview and Introduction
need to be updated. You should upgrade the support level of the HMC to be consistent with
the support that is provided on the servers to which it is attached. In a dual HMC
configuration, both systems must be at the same version and release of the HMC.
To determine the HMC machine code level that is required for the firmware level on any
server, go to the Fix Central website and access the Fix Level Recommendation Tool (FLRT)
on or after the planned availability date for this product. FLRT will identify the correct HMC
machine code for the selected system firmware level. See the Fix Central site:
http://www-933.ibm.com/support/fixcentral/
With HMC code V7R7.7.0 (SP1), the HMC supports Mozilla Firefox 7 through 10 and
Microsoft Internet Explorer 7 through 9.
HMC RAID 1 support
HMCs now offer a high-availability feature. Starting from HMC 7042-CR7 RAID 1 protection
will be enabled by default. This feature is enabling data redundancy using two physical disk
drives.
RAID 1 is also offered on both the 7042-CR6 and the 7042-CR7 (if the feature was removed
from the initial order) as an MES upgrade option.
Blade management
The HMC gives systems administrators a tool for planning, virtualizing, deploying, and
managing IBM Power System servers.
With the introduction of HMC V7R760, the HMC can now manage IBM BladeCenter Power
Blade servers. This management includes support for dual VIOS, live partition mobility
between blades and rack servers, and management of both blades and rack servers from a
single management console.
Comparison of 7042-CR6 and 7042-CR7 HMC models
The 7042-CR6 was withdrawn from marketing in December 2012. For your reference,
Table 2-29 lists a comparison between the 7042-CR6 and the 7042-CR7 HMC models.
Table 2-29 Comparison for 7042-CR6 and 7042-CR7
Feature
CR6
CR7
IBM System x model
x3550 M3
x3550 M4
HMC model
7042-CR6
7042-CR7
Processor
Westmere-EP
Intel Xeon E5
Memory
4 GB
4 GB
DASD
500 GB
500 GB
RAID 1
Optional
Default
Multitech internal modem
Default
Optional
USB ports
Two front, four back, one internal
Two front, four back, one internal
Integrated network
Two on main bus and two on
expansion slot
Four 1 Gb Ethernet
I/O slots
1 PCI Express 2.0 slot
1 PCI Express 3.0 slot
Содержание Power 720 Express
Страница 2: ......
Страница 14: ...xii IBM Power 720 and 740 Technical Overview and Introduction ...
Страница 128: ...114 IBM Power 720 and 740 Technical Overview and Introduction ...
Страница 204: ...190 IBM Power 720 and 740 Technical Overview and Introduction ...
Страница 205: ......