v
In a stand-alone configuration.
Procedure
1.
If you have not already done so, reboot the replacement node, interrupt the
boot process by entering
Ctrl-C
, and then select the option to boot to
Maintenance mode from the displayed menu. You must enter
Y
when prompted
to override the system ID due to a system ID mismatch.
2.
View the system IDs by entering the following command:
disk show -a
Note:
Make note of the old system ID, which is displayed as part of the disk
owner column.
The following example shows the old system ID of 118073209:
*> disk show -a
Local System ID: 118065481
DISK
OWNER
POOL
SERIAL NUMBER
HOME
-------- -------------
-----
-------------
-------------
0b.29
system-1
(
118073209
)
Pool0
J8XJE9LC
system-1
(
118073209
)
0a.27
system-1
(
118073209
)
Pool0
J8Y478RC
system-1
(
118073209
)
.
.
.
3.
Reassign disk ownership (for filer systems) or LUN ownership (for gateway
systems) by using the system ID information obtained from the
disk show
command:
disk reassign -s
old system ID
In the case of the preceding example, the command is:
disk reassign -s 118073209
You can respond
Y
when prompted to continue.
4.
Verify that the disks (or gateway LUNs) were assigned correctly by entering the
following command:
disk show -a
Make sure that the disks belonging to the replacement node show the new
system ID for the replacement node. In the following example, the disks owned
by system-1 now show the new system ID, 118065481:
*> disk show -a
Local System ID: 118065481
DISK
OWNER
POOL
SERIAL NUMBER
HOME
------- -------------
-----
-------------
-------------
0b.17
system-1
(118065481) Pool0
J8Y0TDZC
system-1
(118065481)
0a.17
system-1
(118065481) Pool0
J8Y09DXC
system-1
(118065481)
.
.
.
5.
If the replacement node is in Maintenance mode (showing the *> prompt), exit
Maintenance mode by entering the following command:
halt
After you issue the command, wait until the system stops at the LOADER
prompt.
6.
On the replacement node, enter the following command at the LOADER
prompt to ensure that the new controller module boots in clustered Data
ONTAP:
setenv bootarg.init.boot_clustered true
124
IBM System Storage: N7000 Series Hardware and Service Guide
Содержание N7700
Страница 2: ......
Страница 12: ...x IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 18: ...xvi IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 20: ...xviii IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 42: ...16 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 46: ...20 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 54: ...28 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 162: ...136 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 164: ...138 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 168: ...142 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 181: ......
Страница 182: ... Printed in USA GC26 7953 13 ...