halt
After you issue the command, wait until the system stops at the LOADER
prompt.
2.
On the replacement node, enter the following command at the LOADER
prompt to ensure that the new controller module boots in clustered Data
ONTAP:
setenv bootarg.init.boot_clustered true
3.
If you have not already done so, on the replacement node, enter the following
command at the LOADER prompt to boot the node, and press
Ctrl-C
to
interrupt the boot process when prompted to display the boot menu:
boot_ontap
If you are prompted to override the system ID due to a system ID mismatch,
enter
y
.
4.
Select the
Update flash from backup config
option from the displayed menu.
If you are asked to continue with the update, enter
y
when prompted. The
replacement node boots up and displays the
Waiting for Giveback
message.
5.
Wait until the
Waiting for giveback...
message is displayed on the
replacement node's console and then, on the healthy node, enter the following
command to verify that the NVRAM adapter replacement has been detected
and that the new partner system ID automatically assigned:
node1::*> storage failover show
Takeover
Node
Partner
Possible
State Description
------------
------------
--------
-------------------------------------
node1
node2
-
Waiting for giveback (HA mailboxes)
node2
node1
false
System ID changed on partner (Old:
151759755, New: 151759706), In takeover
6.
From the healthy node, ensure that any coredumps on the replacement node
are saved:
a.
From the healthy node, enter the following command to change to the
advanced privilege level:
set -privilege advanced
You can respond
Y
when prompted to continue into advanced mode. The
advanced mode prompt appears (*>).
b.
From the healthy node, enter the following command:
system node run -node
local-node-name
partner savecore
c.
Wait for savecore command to complete before issuing the giveback. You
can enter the following command to monitor the progress of the savecore
command:
system node run -node
local-node-name
partner savecore -s
d.
From the healthy node, enter the following command to return to the
admin privilege level:
set -privilege admin
7.
Complete the following substeps after the replacement node is displaying the
Waiting for Giveback
message:
a.
Enter the following command from the healthy node:
storage failover giveback -ofnode
replacement_node_name
As the replacement node boots up, it might display the prompt warning of
a system ID mismatch and asking to override the system ID. You can
respond
Y
. The replacement node takes back its storage, completes booting
up, and then reboots and is again taken over by the healthy node.
122
IBM System Storage: N7000 Series Hardware and Service Guide
Содержание N7700
Страница 2: ......
Страница 12: ...x IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 18: ...xvi IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 20: ...xviii IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 42: ...16 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 46: ...20 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 54: ...28 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 162: ...136 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 164: ...138 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 168: ...142 IBM System Storage N7000 Series Hardware and Service Guide ...
Страница 181: ......
Страница 182: ... Printed in USA GC26 7953 13 ...